The effect of increased environmental temperature on the behavior of physiologic parameters in bicycle ergometry within the scope of the physical endurance limit
Frauendorf, H.; Gelbrich, W.; Vildosola, J.; Küchler, G.
Zeitschrift für die Gesamte Hygiene und ihre Grenzgebiete 35(6): 354-357
1989
ISSN/ISBN: 0049-8610 PMID: 2800633 Document Number: 338365
For determination of the endurance limit range, 8 healthy male probands aged between 20 and 26 years loads had carried out for one hour on a bicycle ergometer at an ambient temperature of +20 degrees C, +28 degrees C and +35 degrees C. Staying in an ambient temperature of 35 degrees C leads to a decrease in the physical endurance limit in an order of magnitude of 10 W. At 20 degrees C, in the endurance range the following values result (mean +/- s): load 68+/- 10.3 W, heart rate 113.6 +/- 5.8 beats per min., net heart rate 31.8 +/- 2.4 beats per min., oxygen uptake 1340 +/- 170 ml per min., auditory canal temperature 36.5 +/- 0.24 degrees C, sweat rate 275 +/- 143 g. At 35 degrees C, the endurance limit is attained at the following values: 57 +/- 10.6 W, heart rate 125 +/- 11.8 beats per min., net heart rate 27.4 +/- 3.6 beats per min., oxygen uptake 1210 +/- 130 ml per min., auditory canal temperature 37.2 +/- 0.3 degrees C, sweat rate 577 +/- 96 g.