Volume estimation of non-caries related enamel defects

Thom, G.

Stomatologie der DDR 39(6): 383-386

1989


ISSN/ISBN: 0302-4725
PMID: 2626768
Document Number: 337493
The volume of wedge shaped defects can be estimated by means of massa suppositoriorum on a plaster cast. The substance are pressed in a graduated pipette. The average relative error is six percent. The absolute error of defects of 2.0, 10.0 respectively 20.0 mm3 ranges from 0.12, 0.6 to 1.2 mm3.