A safe technique for the placement of implantable vascular access devices in patients with thrombocytopenia
Coit, D.G.; Turnbull, A.D.
Surgery Gynecology and Obstetrics 167(5): 429-431
1988
ISSN/ISBN: 0039-6087 PMID: 3175827 Document Number: 313573
This further modification of the Seldinger technique is offered as a safe and effective means of central venous access for placement of implantable infusion devices. It is especially useful in patients with severe thrombocytopenia, even when the cephalic vein is not large enough to accept the catheter directly.
Document emailed within 1 workday
Related Documents
Dal Molin, R.; Hecker, B. 2013: Implantable medical devices MRi safe Studies in Health Technology and Informatics 189: 96-100Pardal Refoyo, J.L.; Muñoz Herrera, A.; Martín Galán, A. 1994: The use of implanted devices for the central venous access in ENT. Placement and aftercare Anales Otorrinolaringologicos Ibero-Americanos 21(2): 177-184
Kajese, T.M.; Drake, R.M.; Ball, J.; Helmer, S.D.; Osland, J.S. 2016: Implantable Central Venous Access Ports Placed in Mastectomy Incision Sites: a Safe and Viable Option American Surgeon 82(12): E341-E343
Di Carlo, I.; Toro, A.; Sofia, M.; Fasone, M.A.; Barbagallo, F.; Russello, D. 2004: Learning curve and early complications of totally implantable venous access devices: is tutoring the solution for the problem? Il Giornale di Chirurgia 25(4): 146-148
Sterchi, J.M.; Fulks, D.; Cruz, J.; Paschold, E. 1986: Operative technique for insertion of a totally implantable system for venous access Surgery Gynecology and Obstetrics 163(4): 381-382
Kincaid, E.H.; Davis, P.W.; Chang, M.C.; Fenstermaker, J.M.; Pennell, T.C. 1999: "Blind" placement of long-term central venous access devices: report of 589 consecutive procedures American Surgeon 65(6): 520
Di Carlo, I.; Lombardo, R.; Russello, D.; Puleo, S. 2000: Totally implantable venous access device inserted during major abdominal operations for cancer. A new technique Hepato-Gastroenterology 47(34): 907-908
Borger van der Burg, B.L.S.; Maayen, R.C.L.A.; van Dongen, T.T.C.F.; Gerben, C.; Eric, C.-.; DuBose, J.J.; Horer, T.M.; Bowyer, M.W.; Hoencamp, R. 2018: Feasibility Study Vascular Access and REBOA Placement: From Zero to Hero Journal of special operations medicine: a peer reviewed journal for SOF medical professionals 18(4): 70-74
Gaudiani, V.A.; Plecha, F.R. 1980: A technique for the placement of popliteal artery to saphenous vein prosthetic grafts for hemodialysis access Surgery Gynecology and Obstetrics 150(5): 729-731
Iorio, O.; Gazzanelli, S.; D'Ermo, G.; Pezzolla, A.; Gurrado, A.; Testini, M.; De Toma, G.; Cavallaro, G. 2018: A Prospective, Comparative Evaluation on Totally Implantable Venous Access Devices by External Jugular Vein versus Cephalic Vein Cutdown American Surgeon 84(6): 841-843
Roca-Tey, R.; Samon, R.; Ibrik, O.; Giménez, I.; Viladoms, J. 2008: Measurement of vascular access blood flow rate during hemodyalisis in 38 patients using the thermodilution technique. a comparative study with the Delta-H method Nefrologia: Publicacion Oficial de la Sociedad Espanola Nefrologia 28(4): 447-452
Baquey, C. 2001: New polymers, surface treatments, bioactive materials: value of vascular access devices Nephrologie 22(8): 399-402
Burstin, R.; Colbert, N.; de Montgolfier, S.; Helenon, C.; Bigot, J.M. 1985: Hepatic chemotherapy by hepatic arterial catheterization with an implantable system allowing permanent vascular access Annales de Gastroenterologie et d'Hepatologie 21(2): 103-108
Weselius, E.-M.; Hartman, J. 2009: Vascular access surgery--technique and teamwork Duodecim; Laaketieteellinen Aikakauskirja 125(4): 415-423
Zák, P.; Tauchman, M.; Maisnar, V.; Podzimek, K.; Mirová, S.; Voglová, J.; Dulícek, P.; Filip, S.; Chrobák, L. 1997: A fully implantable port system for venous access. Personal experience with 91 patients Vnitrni Lekarstvi 43(5): 273-278
Tazza, L.; Mandolfo, S.; Carbonari, L.; Forneris, G.; Di Dio, M.; Palumbo, R.; Gallieni, M.; Bonforte, G.; Carnabuci, A.; Cavatorta, F.; Aloisi, M.; Galli, F. 2010: Vascular access for hemodialysis: recommendations of the Vascular Access Study Group of the Italian Society of Nephrology Giornale italiano di nefrologia: organo ufficiale della Societa italiana di nefrologia 27(5): 508-511
Sviridova, A.A. 2018: Magnetic resonance imaging in patients with implantable devices for treatment of disturbed heart rhythm: review of the current situation Kardiologiia 2018(S3): 4-8
D'Angelo, F.A. 2003: Prospective randomised study of cephalic vein cut-down versus subclavian vein puncture. Technique in the implantation of subcutaneous venous access devices Chirurgia Italiana 55(2): 313
Simoni, G.; Decian, F. 1992: Modification of the in situ saphenous vein technique as vascular access for chronic hemodialysis treatment. Technical note Minerva Chirurgica 47(3-4): 121-123
Cherniavskiĭ, A.M.; Kareva, I.E.; Pak, I.A.; Rakhmonov, S.S.; Romanov, A.B.; Pokushalov, E.A. 2013: The use of implantable devices for long-term monitoring of cardiac rhythm after surgical treatment of atrial fibrillation in patients with ischemic heart disease Kardiologiia 53(8): 60-66