Improvement in oxygenation during open chest surgery with lung exclusion by selective continuous positive pressure. Preliminary results in 15 operations
Lefebvre, D.; Grunenwald, D.; Nguyen, H.N.
Annales de Chirurgie 41(6): 482-484
1987
ISSN/ISBN: 0003-3944 PMID: 3314641 Document Number: 298258
Document emailed within 1 workday
Related Documents
Marraro, G.; Vegni, M.; Guarino, A.; Tornaghi, R. 1975: Results of continuous positive airway pressure (CPAP) and continuous positive pressure ventilation (CPPV) in the neonatal idiopathic respiratory syndrome (IRS) Minerva Pediatrica 27(13): 814-829Lovas, A.; Molnár, Z. 2013: T-piece improves arterial and central venous oxygenation in trachestomized patients as compared to continuous positive airway pressure/pressure support ventilation Minerva Anestesiologica 79(5): 492-497
Roeseler, J.; Tremouroux, J.; Soete, M.; Reynaert, M.; Francis, C. 1982: Effects of three types of respiratory assistance (continuous positive pressure, intermittent positive pressure, classical respiratory physiotherapy) on PaO2 and PaCO2 in patients undergoing digestive tract surgery Le Poumon et le Coeur 38(3): 135-142
Metzler, H. 1985: Hemodynamics in right heart damage under continuous positive pressure respiration. An experimental study of the open thorax Der Anaesthesist 34(2): 72-78
Imazu, S.; Yamagiwa, K.; Komatsu, T.; Saito, F.; Noguchi, H.; Takumi, Y. 1978: Effects of continuous positive pressure ventilation on the volume of extravascular lung water Masui. Japanese Journal of Anesthesiology 27(6): 567-572
Shamir, M.; Gozal, Y.; Weiss, Y.; Ronin, L.; Raphael, J. 2002: Asynchronous independent intermittent positive pressure ventilation as a solution to refractory hypoxemia during chest surgery Anesthesiology 97(3): 743-745
Mukubo, M.; Chin, S.; Matsumori, M.; Yamamoto, T.; Okada, M. 1974: Management of respiration of infants after heart surgery. 1. Use of continuous positive airway pressure Kyobu Geka. Japanese Journal of Thoracic Surgery 27(7): 520-523
Manzano Alonso, J.L.; Fernández Losa, J.; Caffarena Raggio, J.M.; Roqués, J.M.; Escribano, J.D. 1975: Application of continuous positive pressure to the respiratory tract in children after heart surgery Revista Espanola de Anestesiologia y Reanimacion 22(3): 304-314
Baehrendtz, S.; Hedenstierna, G. 1984: Differential ventilation and selective positive end-expiratory pressure: effects on patients with acute bilateral lung disease Anesthesiology 61(5): 511-517
Mikołajczyk, W.; Nowosławska, E.; Polis, L.; Zakrzewski, K. 1992: Effect of partial kyphectomy on the improvement of the results of reconstructive surgery in open meningomyelocele Neurologia i Neurochirurgia Polska Suppl 1: 338-339
Kesecioğlu, J.; Telci, L.; Tütüncü, A.S.; Esen, F.; Denkel, T.; Erdmann, W.; Akpir, K.; Lachmann, B. 1996: Effects of volume controlled ventilation with PEEP, pressure regulated volume controlled ventilation and low frequency positive pressure ventilation with extracorporeal carbon dioxide removal on total static lung compliance and oxygenation in pigs with ARDS Advances in Experimental Medicine and Biology 388: 629-636
Bertoletti, F.; Indelicato, A.; Banfi, P.; Capolunghi, B. 2009: Sleep apnoea/hypopnoea syndrome: combination therapy with the Pillar palatal implant technique and continuous positive airway pressure (CPAP). A preliminary report B-ENT 5(4): 251-257
Matsuda; Kawashima, K.; Danno, M.; Tanaka, K.; Okumura, F. 1974: Management of respiration of infants after heart surgery. k. Use of continuous positive airway pressure in ventricular septal defects Kyobu Geka. Japanese Journal of Thoracic Surgery 27(7): 517-520
Kirby, R.R. 2000: Round and round we go, and where we stop, nobody knows: the open lung concept and high-level positive end-expiratory pressure (revisited) Critical Care Medicine 28(5): 1672-1673
Gibson, W.P. 1983: A study of endolymphatic sac surgery. the results after reconstructing the sac versus those in operations that failed to open the lumen and satisfactorily insert a silastic implant Otolaryngologic Clinics of North America 16(1): 181-188
Cheng, Y.; Huang, F.; Zhu, L. 2013: Numerical simulation of the internal noise in the pressure generator of a continuous positive airway pressure ventilator Sheng Wu Yi Xue Gong Cheng Xue Za Zhi 30(2): 312-315
Wiebel, M.; Laier-Groeneveld, G.; Schönhofer, B.; Knape, H.; Hein, H.; Hamm, M.; Fichter, J. 1999: The role of non-invasive positive pressure ventilation in lung volume reduction surgery of pulmonary emphysema--a survey of German hospitals Medizinische Klinik 94(1 Spec No): 81-85
Pruthi, R.K.; Mathew, P.; Valentino, L.A.; Sumner, M.J.; Seremetis, S.; Hoots, W.K. 2007: Haemostatic efficacy and safety of bolus and continuous infusion of recombinant factor VIIa are comparable in haemophilia patients with inhibitors undergoing major surgery. Results from an open-label, randomized, multicenter trial Thrombosis and Haemostasis 98(4): 726-732
Müller-Fassbender, H.; Link, F. 1987: Typing of HLA antigens with monoclonal antibodies. Exclusion of false-positive results and cross reactions Fortschritte der Medizin 105(30): 586-589
Chernick, V.; Vidyasagar, D. 1972: Continuous negative chest wall pressure in hyaline membrane disease: one year experience Pediatrics 49(5): 753-760