Effects of volume controlled ventilation with PEEP, pressure regulated volume controlled ventilation and low frequency positive pressure ventilation with extracorporeal carbon dioxide removal on total static lung compliance and oxygenation in pigs with ARDS
Kesecioğlu, J.; Telci, L.; Tütüncü, A.S.; Esen, F.; Denkel, T.; Erdmann, W.; Akpir, K.; Lachmann, B.
Advances in Experimental Medicine and Biology 388: 629-636
1996
ISSN/ISBN: 0065-2598 PMID: 8798869 Document Number: 455583
Document emailed within 1 workday
Related Documents
Hu, X.; Shen, H.; Li, X.; Chen, J. 2014: Effects of volume-controlled ventilation and pressure-controlled volume- guaranteed mode during one-lung ventilation on circulation, pulmonary function and lung injury Zhonghua Yi Xue Za Zhi 94(13): 1006-1009Riverso, P.; Bernardi, P.L.; Corsa, D.; Morra, M.G.; Paganini, G.; Parigi, F. 1998: A comparison of ventilation techniques in ARDS. Volume controlled vs pressure regulated volume control Minerva Anestesiologica 64(7-8): 339-343
Wathanasormsiri, A.; Preutthipan, A.; Chantarojanasiri, T.; Suwanjutha, S. 2002: Dead space ventilation in volume controlled versus pressure controlled mode of mechanical ventilation Journal of the Medical Association of Thailand 85 Suppl. 4: S1207-S1212
Imazu, S.; Yamagiwa, K.; Komatsu, T.; Saito, F.; Noguchi, H.; Takumi, Y. 1978: Effects of continuous positive pressure ventilation on the volume of extravascular lung water Masui. Japanese Journal of Anesthesiology 27(6): 567-572
Betensley, A.D.; Khalid, I.; Crawford, J.; Pensler, R.A.; DiGiovine, B. 2008: Patient comfort during pressure support and volume controlled-continuous mandatory ventilation Respiratory Care 53(7): 897-902
Makita, K.; Uchida, T.; Toyooka, H.; Amaha, K. 1994: Effects of pressure support ventilation (PSV) or PSV+PEEP on the respiratory function during general anesthesia under spontaneous ventilation Masui. Japanese Journal of Anesthesiology 43(11): 1675-1679
Kassil', V.L.; Kantor, P.S. 1986: Effect of the respiratory rate on the tidal volume and ventilatory minute volume in high-frequency jet-controlled artificial pulmonary ventilation Anesteziologiia i Reanimatologiia 1986(5): 47-48
Wu, G.; Lu, B. 1998: The application of low tidal volume pressure-controlled ventilation in patients with acute respiratory distress syndrome Hunan Yi Ke da Xue Xue Bao 23(1): 57-58
Takaoka, F.; Ruiz Neto, P.; Caputi, A.; Pereira, M.H.; Auler Júnior, J.O.; Do Amaral, R.V. 1986: Cardiac ventriculography in dogs subjected to high frequency jet ventilation and intermittent positive pressure ventilation Revista Paulista de Medicina 104(2): 70-74
Martins, F.M.; Afonso, J.E.; Romaldini, H.; dos Santos, M.L. 1988: Comparison of high-frequency jet ventilation and intermittent positive pressure ventilation in a experimental model of acute respiratory insufficiency Amb: Revista da Associacao Medica Brasileira 34(4): 116-122
Osswald, P.M.; Bender, H.J.; Hartung, H.J.; Klose, R.; Olsson, S.G.; Weller, L. 1983: Effects of positive end-expiratory pressure (PEEP) or prolonged inspiration time on lung mechanics, gas exchange and hemodynamics in differential pulmonary ventilation Der Anaesthesist 32(3): 99-104
Kacmarek, R.M.; Dimas, S.; Reynolds, J.; Shapiro, B.A. 1982: Technical aspects of positive end-expiratory pressure (PEEP): Part II. PEEP with positive-pressure ventilation Respiratory Care 27(12): 1490-1504
Wiebel, M.; Laier-Groeneveld, G.; Schönhofer, B.; Knape, H.; Hein, H.; Hamm, M.; Fichter, J. 1999: The role of non-invasive positive pressure ventilation in lung volume reduction surgery of pulmonary emphysema--a survey of German hospitals Medizinische Klinik 94(1 Spec No): 81-85
Li, J.; Zhang, D-hou.; Huang, X-feng.; Ding, M.; Shu, G-rong. 2005: Comparison of noninvasive positive pressure ventilation and invasive positive pressure ventilation in patients with acute respiratory failure Chinese Medical Sciences Journal 20(2): 150
Kallet, R.H.; Campbell, A.R.; Dicker, R.A.; Katz, J.A.; Mackersie, R.C. 2005: Work of breathing during lung-protective ventilation in patients with acute lung injury and acute respiratory distress syndrome: a comparison between volume and pressure-regulated breathing modes Respiratory Care 50(12): 1623-1631
Tooley, R.; Hirschl, R.B.; Parent, A.; Bartlett, R.H. 1996: Total liquid ventilation with perfluorocarbons increases pulmonary end-expiratory volume and compliance in the setting of lung atelectasis Critical Care Medicine 24(2): 268-273
Harrer, J.; Vít, Z. 1986: The effect of controlled respiration with positive expiratory pressure (PEEP) on the minute cardiac volume in patients after cardiosurgical procedures Rozhledy V Chirurgii: Mesicnik Ceskoslovenske Chirurgicke Spolecnosti 65(1): 42-50
Civetta, J.M.; Shapiro, B.A.; Stevens, P.M. 1977: Positive end-expiratory pressure (PEEP) and intermittent mandatory ventilation (IMV): a discussion Respiratory Care 22(10): 1111 1113-5 1117 Passim
Shpirer, I.; Asherov, J.; Zimlichman, R. 1995: Nasal positive pressure ventilation--renewal of ventilation technique Harefuah 129(12): 586-590
Lovas, A.; Molnár, Z. 2013: T-piece improves arterial and central venous oxygenation in trachestomized patients as compared to continuous positive airway pressure/pressure support ventilation Minerva Anestesiologica 79(5): 492-497