Coefficient of variation of heart rate in the newborn during the first 2 hours of life. Differences according to type of delivery

Ramos Fuentes, F.; Cardesa García, J.J.; Arbués Lacadena, J.; Espinosa Ruiz-Cabal, J.; Pérez González, J.

Anales Espanoles de Pediatria 27(3): 165-168

1987


ISSN/ISBN: 0302-4342
PMID: 3426004
Document Number: 294030
A prospective study of continual heart rate monitoring is made in 57 normal newborn infants in the first two hours after birth. They were all divided into three groups according to their type of delivery. We have estimated the coefficient of variation, whose value quantifies the heart rate variability, obtained by continual monitoring. It was significantly lower (p less than 0.05) in newborns whose mothers had received anaesthesia during labour than in infants born by non-induced vaginal delivery. These results support the sensitivity of this method in order to assess neonatal cardiac readaptation.