Assay of acenocoumarol (Sintrom) in the plasma by liquid chromatography
Guyon, F.; Dupeyron, J.P.; Fabiani, P.
Annales de Biologie Clinique 43(5): 743-745
1985
ISSN/ISBN: 0003-3898 PMID: 4091321 Document Number: 254560
Reversed-phase liquid chromatography was performed on C18 column using a pH 4 buffered water-methanol 45:55 (v/v) mobile phase and ultraviolet detection (307 nm). Warfarin was used as internal standard and dichloro-1,2 ethane as extraction solvent. The analytical recovery was greater than 98 p. cent. The within-day coefficient of variation (CV) was 5 p. cent, while the between day CV was 6.4 p. cent. The limit of detection was 0.02 mg/l.
Document emailed within 1 workday
Related Documents
Hengy, H.; Vollmer, K.O.; Gladigau, V.; Kölle, E.U. 1980: Assay of etozolin and its main metabolite, ozolinone, in plasma by high performance liquid chromatography Arzneimittel-Forschung 30(10): 1788-1790Goldstein, D.S.; Feuerstein, G.F. 1981: Improved reliability of the liquid chromatography--electrochemical detection assay technique for measuring plasma epinephrine Clinical Chemistry 27(3): 508
Puglisi, C.V.; Ferrara, F.J.; de Silva, J.A. 1983: Determination of a pyrimido-benzazepine anxiolytic agent and its 5-hydroxy metabolite in whole blood, plasma and urine by gas--liquid chromatography with electron-capture detection and by high-performance liquid chromatography Journal of Chromatography 275(2): 319-333
Paanakker, J.E.; Thio, J.M.; Van den Wildenberg, H.M.; Kaspersen, F.M. 1987: Assay of vecuronium in plasma using solid-phase extraction, high-performance liquid chromatography and post-column ion-pair extraction with fluorimetric detection Journal of Chromatography 421(2): 327-335
Müller, M.D.; Bosshardt, H.P. 1988: Enantiomer resolution and assay of propionic acid-derived herbicides in formulations by using chiral liquid chromatography and achiral gas chromatography Journal - Association of Official Analytical Chemists 71(3): 614-617
Wilson, R.T.; Groneck, J.M.; Henry, A.C.; Rowe, L.D. 1991: Multiresidue assay for benzimidazole anthelmintics by liquid chromatography and confirmation by gas chromatography/selected-ion monitoring electron impact mass spectrometry Journal - Association of Official Analytical Chemists 74(1): 56-67
Van Rooy, H.H.; Vermeulen, M.P.; Bovill, J.G. 1981: The assay of fentanyl and its metabolites in plasma of patients using gas chromatography with alkali flame ionisation detection and gas chromatography-mass spectrometry Journal of Chromatography 223(1): 85-93
Marunaka, T.; Umeno, Y. 1978: Quantitative determination of 1,3-bis(tetrahydro-2- furanyl)-5-fluoro-2,4-pyrimidinedione and its metabolites in plasma by high-pressure liquid chromatography and gas chromatography-mass fragmentography Journal of Chromatography 157: 321-330
Peat, M.A.; Kopjak, L. 1979: The screening and quantitation of diazepam, flurazepam, chloridazepoxide, and their metabolites in blood and plasma by electron-capture gas chromatography and high pressure liquid chromatography Journal of Forensic Sciences 24(1): 46-54
Diquet, B.; Colin, J.N.; Bonnat, C.; Singlas, E. 1983: Assay of a radiation-sensitizer, misonidazole, by high-performance liquid chromatography Annales Pharmaceutiques Francaises 40(5): 459-464
Lima, P.M.A.; Prado, N.ál.D.; Silva, M.-L.M.; Diniz, R.D.L.; Queiroz, K.M.; César, I.d.C.; Pianetti, G.ér.A.ôn.; Santos, D.A. 2009: Determination of ketoconazole in capsules by high-performance liquid chromatography and microbiological assay Journal - Association of Official Analytical Chemists 92(4): 1076-1081
Lewis, J.L.; Macy, T.D.; Garteiz, D.A. 1989: Determination of nicarbazin in chicken tissues by liquid chromatography and confirmation of identity by thermospray liquid chromatography/mass spectrometry Journal - Association of Official Analytical Chemists 72(4): 577-581
Lemée, V.; Hue, G.; Lahary, A.; Lavoinne, A. 1999: Incidental detection of hemoglobin abnormalities by HbA1c assay with high pressure liquid chromatography Annales de Biologie Clinique 57(6): 713-716
Roberts, A.B.; Nichols, M.D.; Frolik, C.A.; Newton, D.L.; Sporn, M.B. 1978: Assay of retinoids in biological samples by reverse-phase high-pressure liquid chromatography Cancer Research 38(10): 3327-3332
Morrisey, J.L.; Shihabi, Z.K. 1979: Assay of urinary 4-hdyroxy-3-methoxymandelic (vanillylmandelic) acid by liquid chromatography with electrochemical detection Clinical Chemistry 25(12): 2043-2045
Moffat, A.C.; Stead, A.H.; Smalldon, K.W. 1974: Optimum use of paper, thin-layer and gas-liquid chromatography for the identification of basic drugs. 3. Gas-liquid chromatography Journal of Chromatography 90(1): 19-33
Iverson, J.L.; Bueno, M.P. 1981: Evaluation of high pressure liquid chromatography and gas-liquid chromatography for quantitative determination of sugars in foods Journal - Association of Official Analytical Chemists 64(1): 139-143
McMullen, S.E.; Schenck, F.J.; Vega, V.A. 2009: Rapid method for the determination and confirmation of fluoroquinolone residues in catfish using liquid chromatography/fluorescence detection and liquid chromatography-tandem mass spectrometry Journal - Association of Official Analytical Chemists 92(4): 1233-1240
Liu, Y.; Wen, D.; Chen, Z.; Liao, Y.; Liu, H. 2004: Study on thermostability and photo-isomerization of trans-resveratrol by high performance liquid chromatography and liquid chromatography-electrospray ionization-mass spectrometry Se Pu 22(6): 583-588
Date, C.; Tanaka, H.; Yoshikawa, K.; Baba, T.; Hayashi, M.; Owada, K.; Okazaki, K.; Nakayama, Y.; Ishii, R. 1982: Determination of sugars in daily foods by high pressure liquid chromatography and gas liquid chromatography Osaka City Medical Journal 28(2): 67-83