Studies on the significances of ratio of pleural fluid glucose to blood glucose
Chavalittamrong, B.; Pongpipat, D.; Tuchinda, M.
Journal of the Medical Association of Thailand 67(1): 16-20
1984
ISSN/ISBN: 0125-2208 PMID: 6716022 Document Number: 227907
Document emailed within 1 workday
Related Documents
Limthongkul, S.; Charoenlap, P.; Udompanich, V.; Nuchprayoon, C.; Songkhla, Y.N. 1986: Blood-pleural fluid glucose and pleural fluid pH, pCO2 relationship. A report of 80 cases of heterogeneous population with the study after intravenous glucose Journal of the Medical Association of Thailand 69(8): 415-421Kverneland, A.; Kirkegaard, B.C.; Wiesniewski, J.; Svendsen, P.A.; Deckert, T.; Nerup, J. 1986: Evaluation of blood glucose determination and 24-hour urinary glucose excretion as indicators of mean blood glucose as expressed by HbAIc in patients with insulin-dependent diabetes mellitus Ugeskrift for Laeger 148(30): 1899-1901
Wang, X.-l.; Lu, J.-m.; Pan, C.-y.; Mu, Y.-m.; Dou, J.-t.; Ba, J.-m. 2006: Characteristics of the daily blood glucose profiles of impaired glucose tolerance and type 2 diabetes mellitus subjects by continuous glucose monitoring system Zhonghua Yi Xue Za Zhi 86(10): 674-677
Carr, D.T.; Lillington, G.A.; Mayne, J.G. 1970: Pleural-fluid glucose in systemic lupus erythematosus Mayo Clinic Proceedings 45(6): 409-412
Boral, R.C.; Majumder, S.; Das, H.K.; Bose, S.K. 1983: Glucose levels and glucose metabolism in human amniotic fluid at different stages of pregnancy Indian Journal of Medical Research 78: 866-869
Fischer, U. 1971: Insulin effect on transmembranous glucose balance of the isolated perfused rat heart. 3. Behavior of glucose distribution space and intracellular glucose concentration in varying glucose supplies under influence of insulin Acta Biologica et Medica Germanica 27(1): 1-11
Takezaki, T.; Nakao, M.; Niinai, H.; Nakatani, K.; Kawaguchi, R.; Hanaki, C.; Nakao, M. 1994: The influence of blood oxygen tension on the glucose level measured by a handy blood glucose analyzer (Toecho Super) Masui. Japanese Journal of Anesthesiology 43(4): 589-593
Malavige, G.N.; Weerasooriya, N.; de Alwis, N.M.W.; Fernando, D.J.S. 2006: The validity of fasting blood glucose and post-prandial blood glucose measurement as an index of glycaemic control in Sri Lankan patients with type 2 diabetes Ceylon Medical Journal 51(1): 40-41
Charoensri, S.; Khahmahpahte, S.; Thepsuthammarat, K.; Pongchaiyakul, C. 2015: An Evaluation of Blood Glucose Measurement Using TRUEresult Blood Glucose Monitoring System Journal of the Medical Association of Thailand 98(9): 839-846
Schraven, E.; Oertel, S.; Nitz, R.E. 1972: Transport of glucose to the brain: its dependence on blood glucose level and its modification by drugs Arzneimittel-Forschung 22(8): 1250-1255
Sann, L.; Frederich, A. 1983: Course of the blood glucose level after cessation of a glucose infusion in the low-birth-weight infant Pediatrie 38(5): 303-308
Alvarez-Buylla, R.; de Alvarez-Buylla, E.R. 1994: Changes in blood glucose concentration in the carotid body modify brain glucose retention Advances in Experimental Medicine and Biology 360: 293-296
Juang, J.H.; Hsu, L.F.; Lin, J.D.; Huang, B.Y.; Huang, M.J.; Huang, H.S. 1987: Comparison of glucose reflectance meters for self-monitoring of blood glucose in diabetics Journal of the Formosan Medical Association 86(6): 667-671
2002: Even if fasting blood glucose value is quite normal, proceed with a glucose tolerance test MMW Fortschritte der Medizin 144(20): 65
Reach, G.; Aussedat, B.; Choleau, C.; Klein, J.C.; Wilson, G.S. 2000: Continuous measurement of blood glucose: invasive methods using glucose capture Journees Annuelles de Diabetologie de l'Hotel-Dieu 2000: 53-66
Dick, W. 1980: A new hemolysing agent for the determination of blood glucose (venous and capillary) by the glucose dehydrogenase method in the autoanalyzer Ii Journal of Clinical Chemistry and Clinical Biochemistry 18(4): 255-256
Choubtum, L.; Mahachoklertwattana, P.; Udomsubpayakul, U.; Preeyasombat, C. 2002: Accuracy of glucose meters in measuring low blood glucose levels Journal of the Medical Association of Thailand 85(Suppl 4): S1104-S1110
Plum, J.; Erren, C.; Fieseler, C.; Kirchgessner, J.; Passlick-Deetjen, J.; Grabensee, B. 1999: An amino acid-based peritoneal dialysis fluid buffered with bicarbonate versus glucose/bicarbonate and glucose/lactate solutions: an intraindividual randomized study Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis 19(5): 418-428
Blomqvist, G.; Stone-Elander, S.; Halldin, C.; Roland, P.E.; Swahn, C.G.; Haaparanta, M.; Solin, O.; Lindqvist, M.; Widén, L. 1991: Cerebral glucose utilization measured by positron emission tomography. [1-11C]-D-glucose compared with [2-18F]-2-fluoro-2-deoxy-D-glucose Acta Radiologica. Supplementum 376: 171-172
Peterson, K.A.; Peterson, A.M.; Corbett, V.; Tongen, S.; Guzman, M.; Mazze, R. 1994: Comparison of home glucose monitoring with the oral glucose tolerance test to detect gestational glucose intolerance Journal of Family Practice 39(6): 558-563