Cardiac output after burn injury
Porter, J.M.; Shakespeare, P.G.
Annals of the Royal College of Surgeons of England 66(1): 33-35
1984
ISSN/ISBN: 0035-8843 PMID: 6691694 Document Number: 225402
Cardiac output after burn injury has been measured by the non-invasive method of impedance plethysmography. An initial study of 143 normal subjects was undertaken in order to investigate variations in cardiac output with age. Fifteen patients were monitored during resuscitation after extensive burns. Fourteen patients showed a depression of stroke volume below the lower limits of the normal range, derived from the initial study on normal people.
Document emailed within 1 workday
Related Documents
Cai, J.-h.; Chai, J.-k.; Shen, C.-a.; Yin, H.-n.; Zhou, X.-f.; Lu, W.; Hu, Q.-g.; Chi, Y.-f.; Ma, L.; Deng, H.-p.; Zhang, X.-b.; Sun, T.-j.; Han, Y.-f. 2010: Early changes in serum neutrophil elastase in rats with burn, blast injury or combined burn-blast injury and its significance Zhonghua Yi Xue Za Zhi 90(24): 1707-1710Miyamoto, S.; Sesa, Y.; Kon, A.; Yamazaki, A.; Horiuchi, A. 1974: Low output syndrome after open heart surgery (with special reference to the use of a new method for quantification of cardiac output) Nihon Kyobu Geka Gakkai 22(5): 517-518
Ichida, S.; Masaki, S.; Ishihara, M.; Sakakibara, H.; Tanaka, K. 1982: Problem on measurement of cardiac output by earpiece dye dilution method in cases of post operative low output syndrome Rinsho Byori. Japanese Journal of Clinical Pathology 30(6): 678-680
Elkbuli, A.; Polcz, V.; Elghoroury, A.; Young, E.; Hai, S.; Boneva, D.; McKenney, M. 2019: Disparities in Burn Injury Prevalence and Outcomes: Results of a Community-Based Burn Prevention Program American Surgeon 85(2): E106-E107
Dirnhofer, R.; Ranner, G. 1982: Intracerebral hemorrhage in a burn victim--burn hematoma, salvage injury or intra vitam origin? Archiv für Kriminologie 170(5-6): 165-172
Sahn, D.J.; Valdes-Cruz, L.M. 1986: Ultrasound Doppler methods for calculating cardiac volume flows, cardiac output, and cardiac shunts Cardiovascular Clinics 17(1): 19-31
Blalock, S.J.; Bunker, B.J.; DeVellis, R.F. 1994: Measuring health status among survivors of burn injury: revisions of the Burn Specific Health Scale Journal of Trauma 36(4): 508-515
Antiuf'ev, V.F.; Izakov, V.I. 1984: Relation between the duration of cardiac cycles and the rheographic characteristics of cardiac output Fiziologiia Cheloveka 10(1): 153-162
Sheriff, D.D.; Zhou, X. 1994: Influence of cardiac output distribution on cardiac filling pressure during rest and dynamic exercise in dogs American Journal of Physiology 267(6 Pt 2): H2378-H2382
Sahasakul, Y.; Chaithiraphan, S. 1988: Comparison of cardiac output measured by suprasternal Doppler echocardiography and thermodilution in cardiac care unit Journal of the Medical Association of Thailand 71(2): 112-114
Gaudreault, G.; Dumesnil, J.G.; Leblanc, M.H. 1992: Measurement of cardiac output by Doppler echocardiography at the 4 cardiac valves Annales de Cardiologie et d'Angeiologie 41(5): 267-271
Shimizu, H.; Seki, S.; Mizuguchi, A.; Tsuchida, H.; Watanabe, H.; Namiki, A. 1990: Cardiac output monitoring by impedance cardiography in cardiac surgery Masui. Japanese Journal of Anesthesiology 39(4): 508-512
Douard, H.; Blaquière, C.; Oysel, N.; Rougier, P.; Broustet, J.P. 1993: Measurement of cardiac output by CO2 rebreathing technique. a study of reproducibility in the normal subject; application to cardiac insufficiency Archives des Maladies du Coeur et des Vaisseaux 86(3): 341-347
Price, P.; Fowlow, B. 1993: Thermodilution cardiac output determinations: a comparison of iced and refrigerated injectate temperatures in patients after cardiac surgery Heart and Lung: the Journal of Critical Care 22(3): 266-274
Torrado, H.; Lopez-Delgado, J.C.; Farrero, E.; Rodríguez-Castro, D.; Castro, M.ía.J.; Periche, E.; Carriò, M.L.; Toscano, J.E.; Pinseau, A.; Javierre, C.; Ventura, J.L. 2016: Five-year mortality in cardiac surgery patients with low cardiac output syndrome treated with levosimendan: prognostic evaluation of NT-proBNP and C-reactive protein Minerva Cardioangiologica 64(2): 101-113
Reddy, P.S.; Curtiss, E.I.; Bell, B.; O'Toole, J.D.; Salerni, R.; Leon, D.F.; Shaver, J.A. 1976: Determinants of variation between Fick and indicator dilution estimates of cardiac output during diagnostic catheterization. Fick vs. dye cardiac outputs Journal of Laboratory and Clinical Medicine 87(4): 568-576
Wacharasint, P.; Kunakorn, P.; Pankongsap, P.; Preechanukul, R. 2014: Clinical validation of pulse contour and pulse wave transit time-based continuous cardiac output analyses in Thai patients undergoing cardiac surgery Journal of the Medical Association of Thailand 97(Suppl 1): S55-S60
Takenaka, K.; Sakamoto, T. 1981: Ultrasonic determination of cardiac output Nihon Rinsho. Japanese Journal of Clinical Medicine 39(7): 2483-2491
Muchada, R.; Cathignol, D.; Lavandier, B.; Muchada, J.P. 1987: Thermodilution overestimates low cardiac output Cahiers d'Anesthesiologie 35(4): 287-289
Chapman, L.W.; Baker, M.A. 1984: Cardiac output of dogs exercising in the heat American Journal of Physiology 247(1 Pt 2): R124-R126