Efficiency of a staining solution for detecting and measuring the plasma protein film on erythrocytes
Wollmann, C.; Linke, A.
Die Pharmazie 38(6): 417-418
1983
ISSN/ISBN: 0031-7144 PMID: 6193541 Document Number: 215885
Document emailed within 1 workday
Related Documents
Li, X.; Hatanaka, K.; Guo, L.; Tsushima, M.; Kitamura, Y.; Yamamoto, A. 1993: A sensitive peroxidase staining immunoblotting method for measuring total protein S in human plasma Thrombosis and Haemostasis 69(4): 331-334Borodaĭ, E.I.; Senik, I.K.; Averbukh, Z.D.; Bilynskiĭ, B.T.; Rozhankivska, L.V. 1973: Evaluation of the viability of twice-washed erythrocytes suspended in a plasma-substitute solution with albumin Problemy Gematologii i Perelivaniia Krovi 18(8): 22-25
Kawasaki, S.; Mizoue, S.; Yamaguchi, M.; Ohashi, Y. 2008: Influence on tear film after instillation of timolol maleate ophthalmic gel-forming solution examination by a tear film stability analysis system Nippon Ganka Gakkai Zasshi 112(6): 539-544
Gabr, Y.; Soliman, M.H.; Dawoud, S.; el-Molla, A.; Amin, E.S. 1971: Studies on stabilized human plasma protein solution Acta Biologica et Medica Germanica 27(2): 341-349
Eisman, J.R. 1980: Stable plasma protein solution (SPPS) and myocardial infarction Medical Journal of Australia 1(5): 239
Chen, Q.; Fu, J.; Yang, G. 1997: A study on the significance of p53 gene mutation, P53 protein positive staining and PCNA staining Hua Xi Kou Qiang Yi Xue Za Zhi 15(2): 119-122
Pehr, F.; Nosek, J. 1975: Separation of venous blood erythrocytes in uranium works miners by centrifuging in dextran solution into metabolically young and old mature erythrocytes Casopis Lekaru Ceskych 114(3): 83-87
Sattar, N.; McMillan, D.C. 1998: Association between plasma plasminogen activator inhibitor-1 and survival in colorectal cancer. Measuring C reactive protein concentrations may be more useful Bmj 317(7160): 750-751
Ho Ngoc-Ta Trung, A.; Sirois, G. 1987: Influence of plasma pH on quinidine uptake by erythrocytes: estimation of free drug fraction in plasma from blood/and erythrocyte/plasma concentration ratios Pharmaceutica Acta Helvetiae 62(2): 61-64
Von Finck, M.; Schmidt, R.; Schneider, W.; Feine, U. 1986: The quality of washed autotransfused erythrocytes. the elimination of plasma hemoglobin, osmotic fragility and survival rate of retransfused erythrocytes Der Anaesthesist 35(11): 686-692
Ramsay, G.; Ledingham, I.M. 1987: Resuscitation in haemorrhagic shock--pulmonary and renal effects: an adverse effect of stabilised plasma protein solution on renal function? Circulatory Shock 22(3): 261-268
Crooks, H.E. 1980: A device for checking the speeds and quality of X-ray films and efficiency of film processors Radiography 46(545): 128-131
Lev, M.I.; Tatarnikov, V.M.; Korliakov, S.V.; Konoplina, L.M. 1979: Comparative efficiency of "transport" culture media for detecting meningococci Voenno-Meditsinskii Zhurnal 3: 40-42
Patel, S.B.; Cook, P.R. 1983: The DNA-protein cross: a method for detecting specific DNA-protein complexes in crude mixtures EMBO Journal 2(1): 137-142
Burbelo, P.D.; Kisailus, A.E.; Peck, J.W. 2002: Detecting protein-protein interactions using Renilla luciferase fusion proteins Biotechniques 33(5): 1044-8 1050
Dieppe, P.; Brandt, K.D.; Lohmander, S.; Felson, D.T. 1995: Detecting and measuring disease modification in osteoarthritis. the need for standardized methodology Journal of Rheumatology 22(2): 201-203
Ferrero, L.; Pissavini, M.; Marguerie, S.; Zastrow, L. 2003: Efficiency of a continuous height distribution model of sunscreen film geometry to predict a realistic sun protection factor Journal of Cosmetic Science 54(5): 463-481
Pytel', I.A.; Shapiro, S.B. 1977: Clinical value of detecting epithelial cells and erythrocytes in urine in urologic diseases Laboratornoe Delo 4: 198-203
Thiery, G.; Ducousso, R. 1973: "In vivo" fixation of the lung using glutaraldehyde vapors. Attempt at measuring the thickness of the liquid film covering the alveoli Le Poumon et le Coeur 29(2): 167-173
Au, Y.K.; Reynolds, M. 1991: Goldmann tonometry and fluorescein solution: a way to avoid contact lens staining Clao Journal: Official Publication of the Contact Lens Association of Ophthalmologists Inc 17(4): 256-257