A rapid and simple assay to determine if macroamylase is the cause of hyperamylasemia

Levitt, M.D.; Ellis, C.

Gastroenterology 83(2): 378-382

1982


ISSN/ISBN: 0016-5085
PMID: 6177576
Document Number: 192541
Macromolecules are known to precipitate selectively in concentrated solutions of polyethylene glycol. This report describes the use of polyethylene glycol 6000 to distinguish macroamylase from normal-sized serum amylase. Preliminary studies indicated that a PEG concentration of 12% and a 10-min incubation at 37 degrees C separated normal serum amylase from macroamylase. Using these conditions, study of 18 macroamylase-containing sera showed precipitation of at least 73% of the amylase activity. In contrast, in 46 normal sera and 16 hyperamylasemic (but not macroamylasemic) sera, less than 52% of the amylase activity was precipitated by polyethylene glycol. This test provides a rapid, simple, and accurate means of determining if macroamylasemia is the cause of hyperamylasemia.