Histopathologic examination of a globe containing an intraocular implant
Howard, G.M.; Praeger, D.L.
Annals of Ophthalmology 14(2): 197-199
1982
ISSN/ISBN: 0003-4886 PMID: 7092029 Document Number: 187251
A patient had both cataracts removed and a Copeland pseudophakos was implanted in one eye. Both globes were retained at autopsy for histopathologic study. The globe containing the implant did not show evidence of acute or chronic inflammation of the anterior segment, nor did it display signs suggesting secondary glaucoma. Some erosion of the iris pigment epithelium was present. In general, the globe appeared to tolerate the implant.
Document emailed within 1 workday
Related Documents
Watanabe, Y.; Ueda, T.; Yamauchi, Y.; Yoshimura, M.; Tamai, Y.; Izumi, S.; Moriwaki, Y.; Yamada, M.; Inatomi, M.; Koide, R. 1998: Change in intraocular pressure after intraocular lens implant during a follow-up period of over 10 years Nippon Ganka Gakkai Zasshi 102(1): 54-58Chorągiewicz, T.; Nowomiejska, K.; Wertejuk, K.; Koss, M.J.; Thaler, S.; Sorrentino, S.; Forlini, M.; Jünemann, A.G.M.; Rejdak, R. 2015: Surgical treatment of open globe trauma complicated with the presence of an intraocular foreign body Klinika Oczna 117(1): 5-8
Noro, T.; Nakamoto, K.; Sato, M.; Yasuda, N.; Ito, Y.; Ogawa, S.; Nakano, T.; Tsuneoka, H. 2014: Correlation of intraocular pressure variation after visual field examination with 24-hour intraocular pressure variations in primary open-angle glaucoma Nippon Ganka Gakkai Zasshi 118(10): 831-837
Esposito, M.; Thomsen, P.; Ericson, L.E.; Lekholm, U. 1999: Histopathologic observations on early oral implant failures International Journal of Oral and Maxillofacial Implants 14(6): 798-810
Böhm, W.; Schnyder, U.W. 1974: The importance of histopathologic examination in diagnosis of skin diseases Therapeutische Umschau. Revue Therapeutique 31(5): 325-328
Trinh Quy, Y.; Lesure, P.; Petry, L.; Duprez, K.; George, J.L. 1992: Risk of infection after cataract surgery with intraocular implant Agressologie: Revue Internationale de Physio-Biologie et de Pharmacologie Appliquees Aux Effets de l'Agression 33(Special Issue 3): 137-139
Woźniak, F.; Borzecki, Z.; Swies, Z. 1991: Histopathologic and histochemical examination of rat liver after prolonged experimental application of potassium bichromate Annales Universitatis Mariae Curie-Sklodowska. Sectio D: Medicina 46: 65-68
Spiegel, D.; Kobuch, K.; Hill, R.A.; Gross, R.L. 1999: Schlemm's canal implant: a new method to lower intraocular pressure in patients with POAG? Ophthalmic Surgery and Lasers 30(6): 492-494
Verzella, F. 1981: Microsurgery of the lens--extracapsular technique, phacoemulsification and intraocular implant in the posterior chamber Bulletin de la Societe Belge d'Ophtalmologie 198(2): 53-54
Hagan, J.C.; Kutryb, M.J. 2009: Cataract and intraocular implant surgery concerns and comments posted at two internet eye care forums Missouri Medicine 106(1): 78-82
Margo, C.E. 1998: Microscopic examination of surgical margins of intraocular tumors excised en bloc Ophthalmic Surgery and Lasers 29(8): 692-694
Lang, E.K.; Johnson, B.; Chance, H.L.; Enright, J.R.; Fontenot, R.; Trichel, B.E.; Martin, E.C. 1972: Assessment of avascular renal mass lesions: the use of nephrotomography, arteriography, cyst puncture, double contrast study and histochemical and histopathologic examination of the aspirate Southern Medical Journal 65(1): 1-10
Nakamura, Y.; Sakurai, I.; Yamada, Y.; Miyata, T. 1981: Reconstituted collagen in experimental eye surgery. 1. Collagen sponge as an intraocular implant Nippon Ganka Gakkai Zasshi 85(9): 1312-1316
Lops, D.; Mosca, D.; Müller, A.; Rossi, A.; Rozza, R.; Romeo, E. 2011: Management of peri-implant soft tissues between tooth and adjacent immediate implant placed into fresh extraction single socket: a one-year prospective study on two different types of implant-abutment connection design Minerva Stomatologica 60(9): 403-415
McLaughlin, S.A.; Ramsey, D.T.; Lindley, D.M.; Gilger, B.C.; Gerding, P.A.; Whitley, R.D. 1995: Intraocular silicone prosthesis implantation in eyes of dogs and a cat with intraocular neoplasia: nine cases (1983-1994) Journal of the American Veterinary Medical Association 207(11): 1441-1443
Jabłoński, J.; Kozak, U.; Bedkowski, Z. 1990: Intraocular pressure after cataract extraction with implantation of an intraocular lens Klinika Oczna 92(9-10): 171-172
Yudhasompop, N.; Wangsupadilok, B. 2012: Effects of phacoemulsification and intraocular lens implantation on intraocular pressure in primary angle closure glaucoma (PACG) patients Journal of the Medical Association of Thailand 95(4): 557-560
Rehák, J. 1992: Neovascular glaucoma and intraocular pressure: I. Pathogenesis of increased intraocular pressure and therapy (a review of historical and current therapeutic modalities) Acta Universitatis Palackianae Olomucensis Facultatis Medicae 133: 71-73
Atagi, K.; Araie, M.; Ando, K.; Kohda, F.; Shimizu, K.; Yamagami, S. 1992: Intraocular lens implantation after glaucoma filtering surgery--time course of changes in intraocular pressure control and filtering blebs Nippon Ganka Gakkai Zasshi 96(10): 1274-1281
Kovalev, I.F. 1974: Disputable problems of determination of hydrodynamic indicators of regulation of intraocular pressure (physiological role of intraocular pressure) Oftalmologicheskii Zhurnal 29(1): 21-28