Dermal contact dermatitis to a disposable electrode plate

Hogan, K.P.; Wyre, H.W.

Cutis 27(2): 157-158

1981


ISSN/ISBN: 0011-4162
PMID: 7226883
Document Number: 175225
A 50-year-old man developed a dermal type of allergic contact dermatitis after exposure to a disposable electrosurgical electrode. Patch testing did not determine the allergenic component, but the electrode contained none of the substances known to cause dermal contact dermatitis.