Prospective analysis of Hemodialysis Reliable Outflow (HeRO) vascular access graft vs. cuffed catheter access in hemodialysis
Provenzano, R.; LaFleur, P.; McFadden, L.; LaFleur, M.; Lorelli, D.
Nephrology News and Issues 29(12): 30
2015
ISSN/ISBN: 0896-1263 PMID: 26677595 Document Number: 16800
The Hemodialysis Reliable Outflow (HeRO) graft was compared to the cuffed catheter in end-stage renal disease patients. All consented patients were evaluated for HeRO graft placement. Eligible patients that did not receive a graft were enrolled in the control group. Participants who had not exhausted peripheral venous access sites suitable for fistulas and grafts were excluded. Differences in quality of life and incidence of bacteremia, vascular interventions, hospitalizations, and death were evaluated over one year. In thirty-three patients included in the analysis--16 HeRO, 17 control--significantly fewer bacteremia events (93.8% vs. 64.7%) and a significantly increased number of vascular interventions (64.7% vs. 25%) were reported for the HeRO versus Control group. The increased interventions in the HeRO group may be due to the two-step placement process.