Echography, laparoscopy and histology in diffuse liver diseases

Heilmann, S.

Münchener Medizinische Wochenschrift 122(10): 339-342

1980


ISSN/ISBN: 0341-3098
PMID: 6445501
Document Number: 154638
The incidence of error of echography (21.0%), laparoscopy (15.0%) and histology (17.4% was investigated in 504 cases of diffuse liver disease. In the assessment of fatty liver, acute fatty liver, fatty cirrhosis and fibroses the accuracy of echography was comparable to that of laparoscopy and histology. A prerequisite for this is that the assessment of the spleen is given particular attention during the diagnosis of diffuse liver diseases. The assessment of diffuse liver diseases demands a high degree of training of the echography diagnostician.