Evaluation of homogeneous enzyme immunoassay of serum thyroxine with the Gilford 3500 analyzer
Cruse, K.L.
Clinical Chemistry 25(8): 1469-1471
1979
ISSN/ISBN: 0009-9147 PMID: 378466 Document Number: 143791
I evaluated homogeneous enzyme immunoassay (EMIT) of serum thyroxine with the Gilford 3500 analyzer. The samples are pretreated before quantitation on the Gilford 3500; the procedure thereafter is entirely mechanized. Forty-four samples may be analyzed per run. Precision and accuracy are good, and results correlate well with those by radioimmunoassay.
Document emailed within 1 workday
Related Documents
Piketty, M.L.; Bounaud, M.P.; Bounaud, J.Y.; Lebtahi, R.; Valat, C.; Askienazy, S.; Begon, F.; Besnard, J.C. 1992: Multicentre evaluation of a two-step automated enzyme immunoassay of free thyroxine European Journal of Clinical Chemistry and Clinical Biochemistry 30(8): 485-492Hintze, G.; Briehl, E.; Jaworek, D.; Kunst, A.; Köbberling, J. 1990: Evaluation of a new enzyme immunoassay system for free thyroxine (Enzymun-Test FT4) Journal of Clinical Chemistry and Clinical Biochemistry 28(6): 427-433
Rootwelt, K. 1971: Thyroxine iodine in the blood. Evaluation of the diagnostic possibilities of serum thyroxine determined by competitive radioimmunoassay, along with serum thyroxine determination combined with the triiodothyronine test and estimation of the free thyroxine factor Tidsskrift for den Norske Laegeforening: Tidsskrift for Praktisk Medicin Ny Raekke 91(21): 1534-1538
Pesce, M.A.; Bodourian, S.H. 1981: Enzyme immunoassay and enzyme inhibition assay of methotrexate, with use of the centrifugal analyzer Clinical Chemistry 27(3): 380-384
Howorth, P.J.; McKerron, C.G.; Marsden, P. 1975: Evaluation of a kit (Thyrolute) for the combined determination of serum total thyroxine and sequential free thyroxine index using Sephadex G-25 and 125I-thyroxine Annals of Clinical Biochemistry 12(5): 200-206
Wallace, J.E.; Harris, S.C.; Shimek, E.L. 1980: Evaluation of an enzyme immunoassay for determining diazepam and nordiazepam in serum and urine Clinical Chemistry 26(13): 1905-1907
Ropero-Miller, J.D.; Garside, D.; Goldberger, B.A. 1997: Automated on-line hydrolysis of benzodiazepines improves sensitivity of urine screening by a homogeneous enzyme immunoassay Clinical Chemistry 43(9): 1659-1660
Dwenger, A.; Schweitzer, G.; Pape, H.C.; Lehmann, U. 1992: Determination of human neutrophil elastase in bronchoalveolar lavage fluid: homogeneous immunoactivation versus heterogeneous enzyme immunoassay European Journal of Clinical Chemistry and Clinical Biochemistry 30(11): 785-786
Rehak, N.N.; Andersen, T.E. 1989: Evaluation of Gilford chemistry control interference with the chloride method in the Beckman Synchron CX3 System analyzer: cumulative effect of bromide on chloride results Clinical Chemistry 35(7): 1538
Jaouhari, J.; Schiele, F.; Dragacci, S.; Tarallo, P.; Siest, J.P.; Henny, J.; Siest, G. 1992: Avidin-biotin enzyme immunoassay of osteocalcin in serum or plasma Clinical Chemistry 38(10): 1968-1974
Rudolf, K.; Rudolf, H.; Rüting, M.; Falkenhagen, D. 1988: Behavior of the basal and stimulated serum level of thyroid stimulating hormone and determination of thyroxine, thyroxine- binding capacity and free thyroxine index in females with chronic uremia Zeitschrift für die Gesamte Innere Medizin und ihre Grenzgebiete 43(20): 590-592
Naemura, J.R.; Radka, S.F. 1993: Detection of oncostatin M in human plasma and serum by a sensitive enzyme immunoassay Lymphokine and Cytokine Research 12(3): 187-190
Frantzen, F.; Faaren, A.L.; Alfheim, I.; Nordhei, A.K. 1998: Enzyme conversion immunoassay for determining total homocysteine in plasma or serum Clinical Chemistry 44(2): 311-316
Jürgen Westermann; Demir, A.; Herbst, V. 2004: Determination of Cortisol in Saliva and Serum by a Luminescence-Enhanced Enzyme Immunoassay Clinical Laboratory 50(1-2): 11-24
Hinds, J.A.; Pincombe, C.F.; Morris, H.; Duffy, P. 1986: Competitive solid-phase enzyme immunoassay for measuring digoxin in serum Clinical Chemistry 32(1 Part 1): 16-21
Hsu, W.S.; Hsieh, Y.Y.; Chen, J.S.; Lin, M.S.; Su, C.T.; Shu, M.Y.; Hsu, J.C. 1983: Measurement of serum digoxin concentration by radioimmunoassay and by enzyme-multiplied immunoassay technique Journal of the Formosan Medical Association 82(12): 1257-1268
Ng, M.L.; Rajna, A.; Khalid, B.A. 1987: Enzyme immunoassay for simultaneous measurement of autoantibodies against thyroglobulin and thyroid microsome in serum Clinical Chemistry 33(12): 2286-2288
Hirota, K.; Kamashima, T. and Masayuki Totani 2001: Detection of Anti-Ovalbumin IgG in Serum by Immune Complex Transfer Enzyme Immunoassay Clinical Laboratory 47(5-6): 213-217
De Keijzer MH; Perkins S; Motta V; Morelli D; Cristol JP; Dupuy AM; Hong Y; Watanabe S; Waerdt C; Grunewald RW 2009: Multi-Site, Multi-Country Evaluation of Analytical and Operational Performance of a Low-Mid Volume Chemiluminescent Immunoassay Analyzer Clinical Laboratory 55(9-10): 363-370
Tunn, S.; Pappert, G.; Willnow, P.; Krieg, M. 1990: Multicentre evaluation of an enzyme-immunoassay for cortisol determination Journal of Clinical Chemistry and Clinical Biochemistry 28(12): 929-935