Temperature gradients and prediction of flap viability

Gaiziunas, A.G.; Hast, M.H.

Journal of Otolaryngology 5(5): 399-402

1976


ISSN/ISBN: 0381-6605
PMID: 792468
Document Number: 104240
This study validates a simple clinical method used to determine optimum time for flap transference. Temperature was used as an indirect measurement to determine blood flow. By means of a needle thermocouple, temperature differences in a variety of flaps were measured. Differences between the base and most distal portion from the blood supply were recorded. The method was first developed on the dog and then applied to patients. It was found that temperature differences of 2.5 degrees C or less insured flap success. Greater temperature differences increased the chance of necrosis.