A system for controlled microwave heating of small samples
Walker, C.M.; Huizings, A.H.; Voss, W.A.; Tinga, W.R.
Journal of Microwave Power 11(1): 29-32
1976
ISSN/ISBN: 0022-2739 PMID: 1046073 Document Number: 102341
A system for the controlled thawing and heating of small samples in a waveguide is described. A means of maintaining constant absorbed power within the sample over a wide range of sample parameters is a major feature of the system. Provision for sensing the melting point of immersed samples is included. Samples are continuously rotated to improve heating uniformity.
Document emailed within 1 workday
Related Documents
1993: Microwave heating of baby milk bottles Kinderkrankenschwester: Organ der Sektion Kinderkrankenpflege 12(3): 87Daels, J. 1976: Microwave heating of the uterine wall during parturition Journal of Microwave Power 11(2): 166-167
Sigman-Grant, M.; Bush, G.; Anantheswaran, R. 1992: Microwave heating of infant formula: a dilemma resolved Pediatrics 90(3): 412-415
Sibony, M.; Commo, F.; Callard, P.; Gasc, J.M. 1995: Enhancement of mRNA in situ hybridization signal by microwave heating Laboratory Investigation; A Journal of Technical Methods and Pathology 73(4): 586-591
Sasaki, K.; Mori, Y.; Honda, W.; Miyake, Y. 1998: Selection of biological indicator for validating microwave heating sterilization PDA Journal of Pharmaceutical Science and Technology 52(2): 60-65
Shrivastav, S.; Joines, W.T.; Jirtle, R.L. 1985: Effect of 5-hydroxytryptamine on tissue blood flow and microwave heating of rat tumors Cancer Research 45(7): 3203-3208
Shin, H.J.; Kalapurakal, S.K.; Lee, J.J.; Ro, J.Y.; Hong, W.K.; Lee, J.S. 1997: Comparison of p53 immunoreactivity in fresh-cut versus stored slides with and without microwave heating Modern Pathology: An Official Journal of the United States and Canadian Academy of Pathology Inc 10(3): 224-230
Ryan, K.L.; Jauchem, J.R.; Tehrany, M.R.; Boyle, H.L. 2002: Platelet-activating factor does not mediate circulatory failure induced by 35-GHz microwave heating Methods and Findings in Experimental and Clinical Pharmacology 24(5): 279-286
Yokoi, H.; Nonoguchi, K.; Kishishita, M.; Iwai, M.; Higashitsuji, H.; Fujita, J. 1996: Use of AmpliSensor to quantitate gene expression in small amounts of samples: comparison with the quantitative RT-PCR method using CCD imaging system Rinsho Byori. Japanese Journal of Clinical Pathology 44(9): 847-852
Barker, K.R.; Gooding, G.V.; Elder, A.S.; Eplee, R.E. 1972: Killing and preserving nematodes in soil samples with chemicals and microwave energy Journal of Nematology 4(2): 75-79
Iaichnikov, I.K.; Medvedeva, G.I.; Abdullin, G.Z. 1980: Effect of local heating of the hypothalamus and whole-body heating on rabbit adrenal cortical activity Patologicheskaia Fiziologiia i Eksperimental'naia Terapiia 5: 71-73
Dzhichonaia, V.M.; Tvauri, M.P. 1973: System for heating mineral water Voenno-Meditsinskii Zhurnal 5: 89-90
Harald König; Heiko-Lestin, G.; Brinkmann, T.; Augsten, M.; Kotira, B. 2007: Semiquantitative Measurement of Drugs in Urine Samples and Measurement of Pharmaceutical Active Substances in Serum Samples Using the Beckman Coulter Synchron LX20® PRO Clinical System Clinical Laboratory 53(1-2): 11-16
Emilia del Pino, M.; Rosado, R.ón.H.; Azuela, A.; Graciela Guzmán, M.; Argüelles, D.; Rodríguez, C.; Rosado, G.M. 2006: Effect of controlled volumetric tissue heating with radiofrequency on cellulite and the subcutaneous tissue of the buttocks and thighs Journal of Drugs in Dermatology: Jdd 5(8): 714-722
Kobayashi, T.; Kida, Y.; Matsui, M.; Amemiya, Y. 1990: Interstitial hyperthermia of malignant brain tumors using implant heating system (IHS) No Shinkei Geka. Neurological Surgery 18(3): 247-252
Liu, Q.C. 1986: The hygienic evaluation of dwelling room microclimate of the district central heating system in an urban area Zhonghua Yu Fang Yi Xue Za Zhi 20(1): 3-5
Ohnuma, O.; Shirata, T.; Suzuki, T.; Sato, M.; Kanouchi, K.; Noguchi, N.; Shiraiwa, T.; Kikuchi, M.; Sato, M.; Seino, F.; Okuyama, Y.; Igarashi, M. 2010: Improvement of the system for collecting blood samples, at the Division of Clinical Laboratory in Yamagata University Hospital, based on the complaints of patients: The way to perform the newly-developed 30-min changeover method for collecting blood samples by medical technologists Rinsho Byori. Japanese Journal of Clinical Pathology 58(6): 581-585
Ohmoto, K.; Yoshioka, N.; Tomiyama, Y.; Shibata, N.; Kawase, T.; Yoshida, K.; Kuboki, M.; Yamamoto, S. 2007: Radiofrequency ablation versus percutaneous microwave coagulation therapy for small hepatocellular carcinomas: a retrospective comparative study Hepato-Gastroenterology 54(76): 985-989
Siekierzynski, M.; Czarnecki, C.; Dziuk, E.; Jedrzejczak, W.W.; Szady, J. 1976: Microwave radiation and other harmful factors of working environment in radiolocation: method of determination of microwave effects Journal of Microwave Power 11(2): 144-145
Frégeau, C.J.; Bowen, K.L.; Leclair, B.ît.; Trudel, I.; Bishop, L.; Fourney, R.M. 2003: AmpFlSTR profiler Plus short tandem repeat DNA analysis of casework samples, mixture samples, and nonhuman DNA samples amplified under reduced PCR volume conditions (25 microL) Journal of Forensic Sciences 48(5): 1014-1034