Continuous personal measurement of harmful reducing gases

Schaffernicht, H.; Schreinicke, G.

Zeitschrift für die Gesamte Hygiene und Ihre Grenzgebiete 21(7): 545-547

1975


ISSN/ISBN: 0049-8610
PMID: 1179776
Document Number: 85773
A portable personal measuring instrument is described which enables gaseous reducing substances to be measured by means of a novel type of semiconductor gas detector. The measured values are telemetered to and continuously recorded at a receiving station. In areas with many buildings, the distance between the test person and receiving equipment may be as much as 150 m. The equipment was field and laboratory tested in formaldehyde content measurements. [The device is suggested for use in wood finishing and lacquer facilities.].