Temperatures generated during implant site preparation with conventional drilling versus single-drill method: an ex-vivo human mandible study

Bacci, C.; Lucchiari, N.; Frigo, A.C.; Stecco, C.; Zanette, G.; Dotto, V.; Sivolella, S.

Minerva Stomatologica 68(6): 277-284

2019


ISSN/ISBN: 0026-4970
PMID: 32052615
Document Number: 699099
Bone overheating during osteotomy is a potential cause of necrosis and consequent failure of dental implant osseointegration. The aim of this study is to identify any differences between conventional osteotomy with drills of increasing size and the use of a single drill in terms of the temperature increase in the bone during implant site preparation. Thirty-eight implant sites were prepared in ex vivo human mandibles, 19 using the conventional method with drills of increasing diameter (group A) and 19 using a single-drill method (group B), with no irrigation in either procedure. An infrared thermometer was used to measure the temperature difference (T°) induced by the drills at each site. Student's t-test (with P<0.05) was used to compare the temperature increase induced by the last drill in group A, and by the single drill in group B. The mean ΔT° in group A was 0.64 °C, while in group B it was 1.47 °C. The difference between the temperatures obtained in the two groups was statistically significant (P=0.0073). In statistical terms, the two methods differ significantly in the temperature increase induced by the drilling procedure, but this difference is clinically irrelevant.

Document emailed within 1 workday