Vasoplegic Syndrome after Aortic Valve Replacement

Miyata, K.; Shigematsu, S.

Masui. Japanese Journal of Anesthesiology 65(1): 90-92

2016


ISSN/ISBN: 0021-4892
PMID: 27004393
Document Number: 688989
We report a case of vasoplegic syndrome (VS) after aortic valve replacement in a 65 year old male with aortic stenosis. The patient developed hypotension after separation from cardiopulmonary bypass (CPB). Transesophageal echocardiography revealed well-maintained cardiac function and normal prosthetic valve function. However, his cardiac index was 3.0 l x min(-1) x m(-2) and systemic vascular resistance index (SVRI) was 1100 dynes x sec(-1) x cm(-5) x m(-2). Diagnosing VS, norepinephrine administration was commenced. Since his respiratory status was good, the patient was extubated on the day of surgery. Two days after surgery, catecholamines were discontinued with the stabilization of his circulatory status. However, his respiratory status showed gradual deterioration, and he was re-intubated. Chest X-ray showed bilateral pleural effusion, which was treated by drainage and fluid restriction. With this, his oxygenation improved and he could be extubated 5 days after surgery. Vasoplegic syndrome is a potentially life-threatening complication following cardiac surgery. Hypotension at the time of separation from CPB can be due to multiple factors. Despite an incidence rate of 10%, little is known about VS. We hope that, in future, tailored therapeutic protocols for VS will be developed.

Document emailed within 1 workday