Late Malapposition After Bare-Metal Stent, But Not Bioresorbable Scaffold: Insights on Intraindividual Heterogeneity in Plaque and Device Response
Cortese, B.; Buccheri, D.; Silva Orrego, P.; Biondi-Zoccai, G.
Journal of Invasive Cardiology 27(8): E171-E172
2015
ISSN/ISBN: 1042-3931 PMID: 26232021 Document Number: 682741
We present a case of late acquired bare-metal stent malapposition and uncovered struts, visible at angiography and confirmed by optical frequency domain imaging. In the same patient, an everolimus-eluting biovascular scaffold in another vessel was well apposed and all struts were covered. This case highlights the potential heterogeneity in the evolution of atherosclerotic plaques and response to different devices in the same patient.
Document emailed within 1 workday
Related Documents
Almasswary, A.A. 2009: Very late stent thrombosis in a bare-metal stent, 9 years after implantation Saudi Medical Journal 30(6): 847-850Lemesle, G.; Pinto Slottow, T.L.; Waksman, R. 2009: Very late stent thrombosis after bare-metal stent implantation: case reports and review of the literature Journal of Invasive Cardiology 21(2): E27-E32
Koziński, M.; Jabłoński, M.ła.; Sukiennik, A.; Kubica, J. 2008: A case of very late bare-metal stent thrombosis implanted into right coronary artery Kardiologia Polska 66(7): 794-797; Discussion: 798-799
Park, J.-S.; Kim, Y.-J.; Hong, G.-R. 2007: Thrombosis and acute myocardial infarction as consequences of very late stent malapposition after implantation of a drug-eluting stent Journal of Invasive Cardiology 19(6): E163-E165
Rathore, S.; Terashima, M.; Suzuki, T. 2009: Late-acquired stent malapposition after sirolimus-eluting stent implantation following acute coronary syndrome: angiographic, IVUS, OCT and coronary angioscopic observation Journal of Invasive Cardiology 21(12): 666-667
Wernly, B.; Latib, A.; Ielasi, A.; Jung, C. 2019: A Polymeric Bioresorbable Vascular Scaffold Versus an Everolimus-Eluting Stent in ST-Segment Elevation Myocardial Infarction Journal of Invasive Cardiology 31(9): E271-E272
Shen, L.; Wu, Y.-z.; Zhang, F.; Sun, A.-j.; Zhong, W.; Qian, J.-y.; Ge, J.-b. 2012: Intravascular ultrasound assessment of chitosan/heparin layer-by-layer self assembly coating stent on late stent malapposition and vessel remodeling in porcine model Zhonghua Xin Xue Guan Bing Za Zhi 40(7): 569-574
Jin, Z.-N.; Chen, Y.-D.; Lü, S.-Z.; Song, X.-T.; Zhu, H.-G.; Li, H. 2006: Clinical and angiographic predictors of restenosis after bare metal stent deployment in coronary artery disease patients complicated with diabetes Zhonghua Xin Xue Guan Bing Za Zhi 34(12): 1093-1096
Rollini, F.; Aprile, A.; Politi, L.; Sangiorgi, G.M. 2011: Evaluation of re-endothelization extent at mid-term follow-up after drug eluting balloon plus bare metal stent implantation during primary coronary angioplasty: insight from OCT imaging Minerva Cardioangiologica 59(1): 109-112
Michael, T.T.; Abdel-karim, A-rahman.R.; Papayannis, A.; Lichtenwalter, C.; de Lemos, J.A.; Obel, O.; Addo, T.; Roesle, M.; Haagen, D.; Rangan, B.V.; Saeed, B.; Bissett, J.K.; Sachdeva, R.; Voudris, V.V.; Karyofillis, P.; Kar, B.; Rossen, J.; Fasseas, P.; Berger, P.B.; Banerjee, S.; Brilakis, E.S. 2011: Recurrent cardiovascular events with paclitaxel-eluting versus bare-metal stents in saphenous vein graft lesions: insights from the SOS (Stenting of Saphenous Vein Grafts) trial Journal of Invasive Cardiology 23(6): 216-219
Simsek, C.; Magro, M.; Boersma, E.; Onuma, Y.; Nauta, S.; Daemen, J.; Gaspersz, M.; van Geuns, R.-J.; van der Giessen, W.; van Domburg, R.; Serruys, P. 2011: Comparison of six-year clinical outcome of sirolimus- and paclitaxel-eluting stents to bare-metal stents in patients with ST-segment elevation myocardial infarction: an analysis of the RESEARCH (rapamycin-eluting stent evaluated at Rotterdam cardiology hospital) and T-SEARCH (taxus stent evaluated at Rotterdam cardiology hospital) registries Journal of Invasive Cardiology 23(8): 336-341
Ruiz-Salmerón, R.J.; Pereira, S.ía.; de Araujo, D. 2014: Bioresorbable vascular scaffold collapse causes subacute thrombosis Journal of Invasive Cardiology 26(7): E98-E99
Noamen, A.; Hajlaoui, N.; Ben Ayed, H.; Lahideb, D.; Haggui, A.; Fehri, W. 2019: Clinical Outcomes of Patients Treated with the Bioresorbable Scaffold La Tunisie Medicale 97(11): 1291-1301
Lanjewar, C.P.; Sharma, A.; Sheth, T. 2009: IVUS-guided management of late stent malaposition with peri-stent restenosis with coronary artery aneurysm following drug-eluting stent implantation (paxlitaxel-eluting stent) Journal of Invasive Cardiology 21(5): E87-E90
Wang, X.Z.; Liu, Y.J.; Guo, C.; Han, Y.L. 2019: Three-year coronary angiographic and optical coherence tomography follow-up of bioresorbable vascular scaffold: a case report Zhonghua Xin Xue Guan Bing Za Zhi 47(3): 235-237
Robaei, D.; Back, L.; Ooi, S.-Y.; Pitney, M.; Jepson, N. 2016: Twelve-Month Outcomes with a Bioresorbable Everolimus-Eluting Scaffold: Results of the ESHC-BVS Registry at two Australian Centers Journal of Invasive Cardiology 28(8): 316-322
Latib, A.; Costopoulos, C.; Naganuma, T.; Colombo, A. 2013: Which patients could benefit the most from bioresorbable vascular scaffold implant: from clinical trials to clinical practice Minerva Cardioangiologica 61(3): 255-262
Gruberg, L.; Grenadier, E.; Beyar, R. 1999: Percutaneous closure of a coronary artery aneurysm with a bare stent Journal of Invasive Cardiology 11(3): 141-143
Kadaifchi, S.; Pershukov, I.V.; Peresypko, M.K.; Pia, I.V.; Lazarev, I.A.; Batyraliev, T.A.; Afanas'ev, A.V.; Niiazova-Karben, Z.A.; Petrakova, L.N.; Preobrazhenskiĭ, D.V.; Sidorenko, B.A. 2006: Restenosis after bare-metal stents implantation in small coronary arteries Kardiologiia 46(2): 19-26
Sardar, P.; Chatterjee, S.; Mukherjee, D.; Garratt, K.N. 2012: Steroids for the prevention of restenosis in bare-metal stents--a systematic review and meta-analysis Journal of Invasive Cardiology 24(3): 98-103