A man with a dislocated hip

Valke, L.L.F.G.; Leeuwesteijn, A.E.E.P.M.; Poelhekke, L.M.S.J.

Nederlands Tijdschrift Voor Geneeskunde 159: A8746

2015


ISSN/ISBN: 1876-8784
PMID: 25944070
Document Number: 680081
A 95-year-old male presented with a dislocated hip hemiarthroplasty after falling off his chair. After closed reposition, symptoms of dislocation remained. A control X-ray showed a disassociation of the prosthesis at the head-neck interface. Therefore, open reposition was performed. X-ray control is important to encounter complications, which can occur after reposition.

Document emailed within 1 workday
Secure & encrypted payments