Design of noninvasive measuring system of isovolumetric bladder pressure based on penile cuff pressure
Wang, G.; Wu, H.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi 26(1): 181-183
2009
ISSN/ISBN: 1001-5515 PMID: 19334581 Document Number: 631745
Seeing that the invasive measuring technique has many disadvantages, we have designed a noninvasive technical system for measuring isovolumetric bladder pressure by controlled inflation of a penile cuff. This system is easy-to-use and the measuring result provides quantitative information on isovolumetric bladder pressure during voiding. The doctor can discriminate obstruction from non-obstruction according to the data of measurement and flow rate.
Document emailed within 1 workday
Related Documents
Ohtsubo, T.; Ohishi, S.; Sakio, H.; Umezono, Y. 2002: Variation in the intracuff pressure of the tracheal tube during general anesthesia without nitrous oxide--the comparison of gas-barrier cuff and conventional "high-volume, low-pressure" cuff Masui. Japanese Journal of Anesthesiology 51(7): 750-754Komatsu, H.; Mitsuhata, H.; Hasegawa, J.; Matsumoto, S. 1993: Evaluation of a pressure and volume-relief instrument (modified Brandt's rediffusion system) to prevent increase in endotracheal tube cuff pressure Masui. Japanese Journal of Anesthesiology 42(2): 296-299
Lu, W.; Tsukada, A.; Kawarada, A.; Sasaki, K. 1999: Suitable location and optimum bladder width for the occluding cuff used for indirect arterial blood pressure measurements at the wrist Frontiers of Medical and Biological Engineering: the International Journal of the Japan Society of Medical Electronics and Biological Engineering 9(1): 9-29
Chu, Y.H.; Ho, S.T.; Yi, H.D.; Kan, K.M. 1991: Rediffusion system and cuff pressure of Brandt's endotracheal tube Ma Zui Xue Za Zhi 29(4): 691-695
Schweiger, H.; Zirngibl, H.; Raithel, D. 1984: Potency disorders before and after pelvic artery reconstruction: objectification by measuring penile artery pressure Der Chirurg; Zeitschrift für Alle Gebiete der Operativen Medizen 55(2): 95-99
Azevedo, J.; Arroja, I.; Jacques, A.; Amado, P.; Marques, J.C.; Araújo, V. 1993: The indices of pressure variability by noninvasive ambulatory monitoring of the arterial pressure. A study in 2 normotensive and hypertensive populations Revista Portuguesa de Cardiologia: Orgao Oficial da Sociedade Portuguesa de Cardiologia 12(7-8): 625
Kellerová, E.; Kittová, M.; Kovácik, P. 1978: Noninvasive method of blood pressure measurement in newborns based on Doppler ultrasound phenomenon Bratislavske Lekarske Listy 70(4): 409-418
Chen, X.; Huo, X.; Zhang, S. 2014: Design of portable pressure-pained-detector based on STM32 Zhongguo Yi Liao Qi Xie Za Zhi 38(5): 333-336
Kallet, R.H.; Katz, J.A.; Pittet, J.F.; Ghermey, J.; Siobal, M.; Alonso, J.A.; Marks, J.D. 2000: Measuring intra-esophageal pressure to assess transmural pulmonary arterial occlusion pressure in patients with acute lung injury: a case series and review Respiratory Care 45(9): 1072-1084
Feng, X.; Deng, Q.; Guo, J.; Liang, F. 2013: Study on the design and detection method of a novel blood pressure measurement system Zhongguo Yi Liao Qi Xie Za Zhi 37(3): 173-177
Holzgreve, R.H. 1980: Problems and errors in the measuring and interpretation of blood pressure. Part 1. General technical prerequisites and error possibilities in blood pressure determination Münchener Medizinische Wochenschrift 122(35): 36-38
Holzgreve, H. 1980: Problems and errors in the measuring and interpretation of blood pressure. Part 7. Blood pressure determination in obesity Münchener Medizinische Wochenschrift 122(41 Suppl): 56-60
Quinn, M. 2001: Blood pressure measurement. ABC shows absence of evidence in measuring blood pressure during pregnancy Bmj 323(7316): 805; Author Reply 806
Li, J.; Zhang, D-hou.; Huang, X-feng.; Ding, M.; Shu, G-rong. 2005: Comparison of noninvasive positive pressure ventilation and invasive positive pressure ventilation in patients with acute respiratory failure Chinese Medical Sciences Journal 20(2): 150
Narkiewicz, K.; Furmański, J.; Rynkiewicz, A.; Kubasik, A.; Krupa-Wojciechowska, B. 1991: Evaluation of blood pressure changes and heart rate in young health men based on results of a 24-hour monitoring of pressure Polski Tygodnik Lekarski 46(1-3): 28-31
Porchet, M.; Nussberger, J.; Brunner, H.R.; Waeber, B. 1993: Blood pressure recording in outpatient service: experience with the Sandoz Pressure System Schweizerische Rundschau für Medizin Praxis 82(11): 320-322
Siddiqui, A.; Behrendt, R.; Lafluer, M.; Craft, S. 2013: A Continuous Bedside Pressure Mapping System for Prevention of Pressure Ulcer Development in the Medical ICU: A Retrospective Analysis Wounds: a Compendium of Clinical Research and Practice 25(12): 333-339
Loggie, J. 1988: Blood pressure cuff confusion Pediatrics 81(2): 328-329
Parwani, V.; Hahn, I-Hei.; Krieger, P.; Zajac, P.; Arakaki, D.; Hoffman, R.J. 2006: Assessing endotracheal tube cuff pressure Emergency Medical Services 35(1): 82-84
Matsumura, L.K.; Romaldini, H.; Ferreira Neto, N.; dos Santos, M.L. 1983: Is pulmonary capillary wedge pressure an expression of left atrial pressure during mechanical respiration with positive pressure ventilation? Arquivos Brasileiros de Cardiologia 41(6): 433-435