Successful percutaneous closure of an aortic graft pseudo-aneurysm with a patent foramen ovale occluder device

Cawley, P.J.; Gill, E.; Goldberg, S.

Journal of Invasive Cardiology 20(1): E19-E22

2008


ISSN/ISBN: 1557-2501
PMID: 18174625
Document Number: 620054
Endovascular stent grafts, prosthetic grafts placed over expandable stents, are an alternative therapy for the treatment of arterial aneurysms, pseudo-aneurysms, dissections, penetrating ulcers and coarctations. However, there are limitations to their applicability. This case describes a patient with Takayasu's arteritis, an inflammatory disease of medium- to large-sized vessels, who developed an aneurysm in an open surgically placed aortic graft. The patient had previously undergone two separate surgeries for the treatment of thoracic aortic aneurysms. Due to the potential for reduced morbidity and mortality, endovascular stenting was a rational approach for a focal graft defect. Endovascular stent graft repair could not be performed because the ratio of the required vascular sheath to peripheral vessel size was prohibitive in this patient. Instead, endovascular therapy using an Amplatzer patent foramen ovale occluder device was delivered within the pseudo-aneurysm to seal the connection to the aortic lumen. At 9-month follow up, the patient has done well clinically and has not required any additional procedures.

Document emailed within 1 workday