Integrated modelling for the evaluation of infiltration effects

Schulz, N.; Baur, R.; Krebs, P.

Water Science and Technology a Journal of the International Association on Water Pollution Research 52(5): 215-223

2005


ISSN/ISBN: 0273-1223
PMID: 16248198
Document Number: 593251
The objective of the present study is the estimation of the potential benefits of sewer pipe rehabilitation for the performance of the drainage system and the wastewater treatment plant (WWTP) as well as for the receiving water quality. The relation of sewer system status and the infiltration rate is assessed based on statistical analysis of 470 km of CCTV (Closed Circuit Television) inspected sewers of the city of Dresden. The potential reduction of infiltration rates and the consequent performance improvements of the urban wastewater system are simulated as a function of rehabilitation activities in the network. The integrated model is applied to an artificial system with input from a real sewer network. In this paper, the general design of the integrated model and its data requirements are presented. For an exemplary study, the consequences of the simulations are discussed with respect to the prioritisation of rehabilitation activities in the network.

Document emailed within 1 workday