Implantable flexible electrodes for functional electrical stimulation
Schneider, A.; Stieglitz, T.
Medical Device Technology 15(1): 16-18
2004
ISSN/ISBN: 1048-6690 PMID: 14994633 Document Number: 584309
A manufacturing technology has been developed to fabricate microelectrode systems with reportedly high numbers of electrodes and high reproducibility. The approach leads to flexible microimplants without the need for heavy and large titanium or ceramic housings.
Document emailed within 1 workday
Related Documents
Smith, B.T.; Betz, R.R.; Mulcahey, M.J.; Triolo, R.J. 1994: Reliability of percutaneous intramuscular electrodes for upper extremity functional neuromuscular stimulation in adolescents with C5 tetraplegia Archives of Physical Medicine and Rehabilitation 75(9): 939-945Larsson, L.E. 1994: Functional electrical stimulation Scandinavian Journal of Rehabilitation Medicine. Supplement 30: 63-72
Herberger, K.; Debus, E.; Larena-Avellaneda, A.; Blome, C.; Augustin, M. 2012: Effectiveness, tolerability, and safety of electrical stimulation of wounds with an electrical stimulation device: results of a retrospective register study Wounds: a Compendium of Clinical Research and Practice 24(4): 76-84
Marsolais, E.B.; Kobetic, R. 1987: Functional electrical stimulation for walking in paraplegia Journal of Bone and Joint Surgery. American Volume 69(5): 728-733
Fasano, V.A.; Broggi, G.; Zeme, S. 1988: Intraoperative electrical stimulation for functional posterior rhizotomy Scandinavian Journal of Rehabilitation Medicine. Supplement 17: 149-154
Hines, A.E.; Crago, P.E.; Billian, C. 1993: Functional electrical stimulation for the reduction of spasticity in the hemiplegic hand Biomedical Sciences Instrumentation 29: 259-266
Bajd, T.; Munih, M. 2010: VI.2. Basic functional electrical stimulation (FES) of extremites - an engineer's view Studies in Health Technology and Informatics 152: 343-352
Kramer, H.; Frauendorf, H.; Küchler, G. 1972: The influence of varying parameters on the electromyogram recorded by surface electrodes. II. The influence of distance, surface area and pressure of the electrodes on recordable muscular electrical activity Acta Biologica et Medica Germanica 28(3): 489-496
Braun, Z.; Mizrahi, J.; Najenson, T.; Graupe, D. 1985: Activation of paraplegic patients by functional electrical stimulation: training and biomechanical evaluation Scandinavian Journal of Rehabilitation Medicine. Suppl 12: 93-101
Dobelle, W.H.; Mladejovsky, M.G.; Girvin, J.P. 1974: Artifical vision for the blind: electrical stimulation of visual cortex offers hope for a functional prosthesis Science 183(4123): 440-444
Gordon, T.; Brushart, T.M.; Amirjani, N.; Chan, K.M. 2007: The potential of electrical stimulation to promote functional recovery after peripheral nerve injury--comparisons between rats and humans Acta Neurochirurgica. Supplement 100: 3-11
Bello, A.I.; Rockson, B.E.A.; Olaogun, M.O.B. 2009: The effects of electromyographic-triggered neuromuscular electrical muscle stimulation on the functional hand recovery among stroke survivors African Journal of Medicine and Medical Sciences 38(2): 185-191
Tan, Z.M.; Jiang, W.W.; Yan, T.B.; Wu, W.; Song, R. 2016: Effects of functional electrical stimulation based on normal gait pattern on walking function in subjects with recovery of stroke Zhonghua Yi Xue Za Zhi 96(29): 2342-2346
Murphy, V.G.; Barr, R.E.; Hahn, A.W. 1975: Development of chronically implantable electrodes for monitoring oxygen tension in skeletal muscle Biomedical Sciences Instrumentation 11: 31-36
Wietholt, D.; Block, M.; Isbruch, F.; Böcker, D.; Hammel, D.; Borggrefe, M.; Scheld, H.H.; Breithardt, G. 1993: Therapy of ventricular tachyarrhythmia with implantable cardioverters/defibrillators--mortality and complications using epicardial electrodes Zeitschrift für Kardiologie 82(3): 150-161
Handa, Y.; Handa, T.; Ichie, M.; Murakami, H.; Hoshimiya, N.; Ishikawa, S.; Ohkubo, K. 1992: Functional electrical stimulation (FES) systems for restoration of motor function of paralyzed muscles--versatile systems and a portable system Frontiers of Medical and Biological Engineering: the International Journal of the Japan Society of Medical Electronics and Biological Engineering 4(4): 241-255
Denisov, I.N.; Kvetnoĭ, I.M. 1981: Functional morphology of the myocardium and carotid paraganglion of dogs during electrical stimulation of the carotid sinus nerve in experimental stenocardia Arkhiv Patologii 43(7): 55-58
Skarzynska, B.; Skarzyński, H.; Niemczyk, K. 1996: Brain stem implantable electrodes in management of total deafness after removal of acoustic neuroma--a review of operative approaches Folia Morphologica 55(4): 442-443
Oliskiewicz, W.; Cyrkowicz, A.; Michalak, T.; Traczyk, W.Z. 1970: Changes in electrical impedance between electrodes permanently implanted into rabbits' midbrain Acta Physiologica Polonica 21(6): 821-831
Faghri, P.D.; Glaser, R.M.; Figoni, S.F. 1992: Functional electrical stimulation leg cycle ergometer exercise: training effects on cardiorespiratory responses of spinal cord injured subjects at rest and during submaximal exercise Archives of Physical Medicine and Rehabilitation 73(11): 1085-1093