Bioequivalence study of two fluconazole capsule formulations in healthy volunteers
Pereira, R.; Fidelis, S.; Vanunci, M.L.P.; Oliveira, C.H.; Mendes, G.D.; Abib, E.; Moreno, R.A.
International Journal of Clinical Pharmacology and Therapeutics 42(1): 39-42
2004
ISSN/ISBN: 0946-1965 PMID: 14756386 Document Number: 581403
Objective: To compare the bioavailability of a fluconazole 150 mg capsule formulation from Laboratorio Teuto Brasileiro Ltd., Brazil (test formulation), and Zoltec 150 mg capsule from Laboratorios Pfizer Ltd., Brazil (reference formulation), in 24 volunteers of both sexes. Material and methods: The study was conducted open with randomized 2-period crossover design and a 2-week washout period. Plasma samples were obtained over a 168-hour interval. Fluconazole concentrations were analyzed by combined reversed-phase liquid chromatography and tandem mass spectrometry (LC/MS/MS) with positive ion electrospray ionization using selected ion monitoring method. From the fluconazole plasma concentration vs. time curves the following pharmacokinetic parameters were obtained: AUClast, AUC0-inf and Cmax. Results: Geometric mean of fluconazole/Zoltec 150 mg individual percent ratio was 102.6% for AUClast, 102.2% for AUC0-inf and 109.4% for Cmax. The 90% confidence intervals were 97.3-108.2%, 97.0-107.8%, and 103.1-116.0%, respectively. Conclusion: Since the 90% CI for both Cmax, AUClast and AUC0-inf were within the 80-125% interval proposed by the Food and Drug Administration, it was concluded that fluconazole 150 mg capsule was bioequivalent to Zoltec 150 mg, according to both the rate and extent of absorption.