Evaluation of apically extruded debris in conventional and rotary instrumentation techniques
Bidar, M.; Rastegar, A.Fallh.; Ghaziani, P.; Namazikhah, M.Sadegh.
Journal of the California Dental Association 32(9): 665-671
2004
ISSN/ISBN: 1043-2256 PMID: 15553960 Document Number: 567542
The purpose of this in vitro study was to compare two common techniques, conventional and rotary instrumentation, in debris extrusion. Two hundred mature human teeth with mature apices and less than 15 degrees of root curvature as determined by Schneider's method were selected for use. Teeth were randomly divided into four groups of 50 teeth each and prepared using step-back instrumentation and profile 4 percent Taper Series 29 rotary system at three different speeds: 1,000 rpm, 8,000 rpm and 24,000 rpm. All of the speeds were reduced by contra angle to 1/6 rpm. Extruded debris were collected on pre-weighed vials containing distilled water through the apical foramen during instrumentation. The vials were then dried in a microwave oven at 150 degrees Celsius and weighed again. The difference was recorded as "the weight of the extruded debris." Eight control vials, two for each group, were weighed and filled with distilled water, dried, and reweighed. The mean weight of extruded debris for each group was statistically analyzed. T-student, unilateral variance analysis and Pearson tests were used in this study. Step-back instrumentation (Group 1) produced significantly more debris than other groups. The difference in the amount of debris produced among rotary groups was not significant. Rotary technique could reduce the amount of debris extrusion.