Development of an advanced high speed aseptic filling system

Deguchi, M.; Akers, J.; Yoshida, S.; Matsuo, N.

PDA Journal of Pharmaceutical Science and Technology 57(1): 43-48

2003


ISSN/ISBN: 1079-7440
PMID: 12643506
Document Number: 557124
A new pharmaceutical aseptic vial filling system has been developed based on isolator technology that is also well suited to use in conventional clean rooms. The results of experiments designed to test the microbiological quality of the environment provided by the new filling system in conjunction with an isolator demonstrate that the isolator enclosed filler can be readily decontaminated and that it can maintain an aseptic environment for at least one month under worse case conditions.

Document emailed within 1 workday
Secure & encrypted payments

Development of an advanced high speed aseptic filling system