Laparoscopic removal of a copper intrauterine device from the sigmoid colon
Zeino, M.Y.; Wietfeldt, E.D.; Advani, V.; Ahad, S.; Younkin, C.; Hassan, I.
Jsls Journal of the Society of Laparoendoscopic Surgeons 15(4): 568-570
2011
ISSN/ISBN: 1086-8089 PMID: 22643520 DOI: 10.4293/108680811x13176785204661Document Number: 553056
IUD translocation to the sigmoid colon after uterine perforation is a rare but serious event. Removal of the IUD in such a situation has been recommended because of the risk of complication, such as fistula formation and colonic perforation. We present the case of a 43-year-old female with a copper T380A IUD embedded in the sigmoid colon, which was removed with minimally invasive techniques.
Document emailed within 0-6 h
Related Documents
Cemachovic, I.; Begin, G.F.; Gaché, P. 1992: Endoscopic removal of an intra-uterine device from the sigmoid colon Gastroenterologie Clinique et Biologique 16(8-9): 720-721Samal, S.; Gupta, U.; Agarwal, P. 1998: Displacement of the Cooper-T 200 intrauterine device into the sigmoid colon Journal of Obstetrics and Gynaecology 18(3): 292-293
Prabhu, J.K.; Rani, R.; Nayak, N.K.; Natarajan, P. 2010: Migration of intrauterine contraceptive device into sigmoid colon Journal of Obstetrics and Gynaecology: the Journal of the Institute of Obstetrics and Gynaecology 30(5): 526-527
Hussain, A.; Omar, K.; El-Hasani, S. 2013: Laparoscopic removal of an eroding Mirena coil through the sigmoid colon Hong Kong Medical Journal 19(6): 560.E3
Kumarappan, A.L.; Karthikeyan, M.; Gunaseelan, D.; Ros'aini, P. 2015: Wandering intrauterine contraceptive device: An unusual travel to the sigmoid colon Medical Journal of Malaysia 70(5): 312-313
Kit, O.I.; Gevorkian, I.A.; Kolesnikov, V.E.; Soldatkina, N.V.; Kharagezov, D.A.; Kaĭmakchi, O.Iu. 2014: Laparoscopic combined resection of sigmoid colon, panhysterectomy with removal through vagina stump Khirurgiia 2014(11): 63-65
Lyon, A.; Pandravada, A.; Leung, E.; Rae, D. 2012: Emergency laparoscopic sigmoid colectomy for perforation secondary to intrauterine contraceptive device Journal of Obstetrics and Gynaecology: the Journal of the Institute of Obstetrics and Gynaecology 32(4): 402-403
Munteanu, O.; Cirstoiu, M.; Antoniac, I.; Cirstoiu, C. 2016: Comparison of Pain Level During and After Intrauterine Device Insertion: Levonorgestrel-Releasing Intrauterine System Versus the Copper T Intrauterine Device Environmental Engineering and Management Journal 15(5): 965-972
Gill, R.S.; Mok, D.; Hudson, M.; Shi, X.; Birch, D.W.; Karmali, S. 2012: Laparoscopic removal of an intra-abdominal intrauterine device: case and systematic review Contraception 85(1): 15-18
Campobasso, D.; Ciuffreda, M.; Maestroni, U.; Dinale, F.; Frattini, A.; Ferretti, S. 2014: Laparoscopic removal of an intrauterine contraceptive device migrated into the bladder: a case report Urology Journal 11(4): 1847-1848
Seiler, J.S. 1986: Laparoscopic tubal sterilization combined with removal of an intrauterine contraceptive device. A report of 49 cases Journal of Reproductive Medicine 31(5): 339-342
Andolsek, L.; Teeter, R.A.; Kozuh Novak, M.; Wheeler, R.; Fortney, J.A.; Rosenberg, M.J. 1986: Time to conception after intrauterine device removal importance of duration of use intrauterine device type pelvic inflammatory disease and age International Journal of Gynecology and Obstetrics 24(3): 217-224
Brunie, A.él.; Stankevitz, K.; Nwala, A.A.; Nqumayo, M.; Chen, M.; Danna, K.; Afolabi, K.; Rademacher, K.H. 2021: Expanding long-acting contraceptive options: a prospective cohort study of the hormonal intrauterine device, copper intrauterine device, and implants in Nigeria and Zambia LANCET. Global Health 9(10): E1431-E1441
Brunie, A.él.; Stankevitz, K.; Nwala, A.A.; Nqumayo, M.; Chen, M.; Danna, K.; Afolabi, K.; Rademacher, K.H. 2021: Expanding long-acting contraceptive options: a prospective cohort study of the hormonal intrauterine device, copper intrauterine device, and implants in Nigeria and Zambia LANCET. Global Health 9(10): E1431-E1441
Brunie, A.él.; Stankevitz, K.; Nwala, A.A.; Nqumayo, M.; Chen, M.; Danna, K.; Afolabi, K.; Rademacher, K.H. 2021: Expanding long-acting contraceptive options: a prospective cohort study of the hormonal intrauterine device, copper intrauterine device, and implants in Nigeria and Zambia LANCET. Global Health 9(10): E1431-E1441
Shin, D.G.; Kim, T.N.; Lee, W. 2012: Intrauterine device embedded into the bladder wall with stone formation: laparoscopic removal is a minimally invasive alternative to open surgery International Urogynecology Journal 23(8): 1129-1131
Xue, H.; Xu, N.; Zhang, C. 1998: Corrosion behavior of copper in a copper bearing intrauterine device in the presence of indomethacin Contraception 57(1): 49-53
Zipper, J.A.; Tatum, H.J.; Medel, M.; Pastene, L.; Rivera, M. 1971: Contraception through the use of intrauterine metals. I. Copper as an adjunct to the "T" device. the endouterine copper "T" American Journal of Obstetrics and Gynecology 109(5): 771-774
Xue, H.; Xu, N.; Zhang, C. 1998: Effect of stainless steel on corrosion behavior of copper in a copper-bearing intrauterine device Advances in Contraception: the Official Journal of the Society for the Advancement of Contraception 14(2): 153-160
Gupta, I.; Kaushalya, S.; Gupta, K.R.; Mahajan, U.; Prasad, R.; Ganguly, N.K. 1994: Copper levels and reactive oxygen species in uterine flushings in copper intrauterine contraceptive device users Indian Journal of Medical Research 100: 225-227