Emission volatile organic compounds from new textile floor coverings
Igielska, B.; Pecka, I.; Sitko, E.; Nikel, G.; Wiglusz, R.
Roczniki Panstwowego Zakladu Higieny 53(3): 307-311
2002
ISSN/ISBN: 0035-7715 PMID: 12621886 Document Number: 550852
The emission of formaldehyde and the other volatile organic compounds (toluene, styrene, 4-PC) and total volatile organic compounds (VOCs) from new textile floor coverings was measured with the use of environmental chamber (0.6 m3 capacity) in the following conditions: temperature 23 degrees C, relative humidity 45%, 1 exchange/hour and factor loading 1 m2 m-3. The formaldehyde was determined by using colorimetric method, VOCs by GC method. The tested carpets did not emit formaldehyde. The emission of other volatile organic compounds was very low and fulfill known requirements.