Horner's syndrome secondary to internal jugular catheterization

Taskapan, H.; Oymak, O.; Dogukan, A.; Utas, C.

Clinical Nephrology 56(1): 78-80

2001


ISSN/ISBN: 0301-0430
PMID: 11499663
Document Number: 535853
We present three cases of people who developed Horner's syndrome following repeated attempts for catheterization of the internal jugular vein for hemodialysis. Any other neurologic finding or evidence of mass lesions in the neck or pulmonary apex could not be determined. Horner's syndrome should be considered a possible complication of percutaneous internal jugular vein catheterization for hemodialysis.