Effects of the dual chamber electrocardiostimulation on the systolic and diastolic function of the myocardium

Sedov, V.M.; Nemkov, A.S.; Lebedev, D.S.; Kuznetsov, A.A.; Mar'eva, O.G.

Vestnik Khirurgii Imeni I. I. Grekova 160(3): 16-19

2001


ISSN/ISBN: 0042-4625
PMID: 11517782
Document Number: 531557
An assessment of the indicators of the systolic and diastolic functions of the left ventricle was made in 52 patients against the background of electrostimulation with a dual chamber electro-cardiostimulator with different atrioventricular delays (185, 125 and 79 ms). Different variants of the reactions to electrostimulation with a shorter atrioventricular delay were detected: the positive dynamics of the diastolic indicators was registered in the hypertrophic type of the diastolic dysfunction, aggravation of the diastolic disorders--in the restrictive type.