Recurrent pulmonary emboli and thrombus attached to a permanently implanted pacemaker wire in pregnancy
Bilge, M.; Güler, N.; Eryonucu, B.
Acta Cardiologica 54(2): 97-99
1999
ISSN/ISBN: 0001-5385 PMID: 10378022 Document Number: 502580
We present a case of pacer wire thrombus and recurrent pulmonary emboli in pregnancy associated with a permanent pacemaker. Transthoracic echocardiography demonstrated a thrombus attached to the pacer wire at the point where it crossed the tricuspid valve. After the uncomplicated vaginal delivery, thrombolytic therapy was given. This thrombus persisted despite thrombolytic therapy. Consequently, the patient was referred for cardiac surgery. The suspected cause was confirmed during the surgery.