Detection of lead in environmental objects and biologic materials during monitoring

Liapunov, S.M.; Seregina, I.F.; Okina, O.I.; Golubchikov, V.V.; Kislova, I.V.; Kistanov, A.A.; Shevchenko, E.P.; Sorokina, N.M.

Meditsina Truda i Promyshlennaia Ekologiia 12: 37-44

1998


ISSN/ISBN: 1026-9428
PMID: 9916453
Document Number: 497072
The authors specified methods to detect lead in biologic materials. The quality control covered use of Russian and foreign standard samples, the results proved to agree. Lead was detected by AAS technique (direct and flow-type variants with preliminary concentration of lead) and ELRA method. The authors determined measurement limits sufficient for analysis of complex biologic materials. The measurement range for lead varied from 0.002 mg/kg (plants) to 3,000 mg/kg (soil); the range of serum lead levels was < 0.5-39 mg/dl.