Normal values of F wave in upper extremities of 50 healthy individuals in Iran
Alavian-Ghavanini, M.R.; Samadzadeh, S.; Alavian-Ghavanini, A.
Electromyography and Clinical Neurophysiology 38(5): 305-308
1998
ISSN/ISBN: 0301-150X PMID: 9741009 Document Number: 492032
F wave latency has been shown to be a valuable method in evaluation of a variety of neurologic disorders. We measured F wave values in 50 healthy individuals in Shiraz. Maximum normal F wave latency for median nerve was 25.7 ms for women and 28.5 ms for men with stimulation at the wrist. It was 23 ms for women and 25 ms for men with stimulation at the elbow. Maximum normal F wave latency for ulnar nerve was 26.45 ms for women and 28.9 ms for men with stimulation at the wrist. It was 23.1 ms for women and 25.3 ms for men with stimulation at the elbow. Maximum normal difference in F wave latency between right and left upper extremities with stimulation at the wrist for total group was 2.2 ms for median nerve and 2.4 ms for ulnar nerve. Maximum normal difference in F wave latency between median and ulnar nerve in an extremity with stimulation at the wrist for total group was 2.7 ms. There was statistically significant difference in F wave latency between women and men.