Non-constrained elbow arthroplasty for mutilans deformity in rheumatoid arthritis: a report of six cases

Kudo, H.

Journal of Bone and Joint Surgery. British Volume 80(2): 234-239

1998


ISSN/ISBN: 0301-620X
PMID: 9546451
Document Number: 489321
Six highly unstable elbows with severe bone loss due to rheumatoid arthritis were replaced by a non-constrained, unlinked prosthesis. Bone defects were filled with autogenous bone grafts. The mean follow-up was 4.5 years (2 to 8). The clinical results were excellent in four elbows and good in two, with good varus-valgus stability in all. Radiological follow-up showed no appreciable signs of loosening, and the bone grafts had retained most of their original size, with minimal resorption. There were no major complications such as dislocation, skin necrosis, infection or ulnar neuropathy. The study has shown that the so-called mutilans elbow can be successfully replaced using a properly selected type of non-constrained, unlinked prosthesis with bone grafting of the major defects.