Endoscopic management of uterine perforation with the ENDO-UNIVERSAL surgical stapler

Römer, T.; Lober, R.

Zentralblatt für Gynakologie 120(2): 69-70

1998


ISSN/ISBN: 0044-4197
PMID: 9531709
Document Number: 485870
The management of an uterine perforation occurring during a D & C, in which a bleeding could not be stopped by coagulation per laparoscopiam is described. The closing of the bleeding injury in the uterus wall was performed by ENDO-UNIVERSAL-clip-instrument. The wound was closed and the bleeding stopped. The possibility to manage an uterine perforation with this simple method is reported and discussed.