Improvement of the surface coil of weida low magnetic field imaging system
Guo, J.; Li, X.
Zhongguo Yi Liao Qi Xie Za Zhi 22(2): 95-97
1998
ISSN/ISBN: 1671-7104 PMID: 12019512 Document Number: 485046
By Replacing Litg wire with copper tube (phi 6 mm, thickness 0.7 mm), we increase the WEIDA low magnetic field imaging system surface coil's signal to noise ratio from 12 to 23, quality factor from 60 to 136, and reduce bandwidth from 50 kHz to 30 kHz.
Document emailed within 1 workday
Related Documents
Zhu, M.; Xia, L.; Liu, F. 2014: Unconventional gradient coil designs in magnetic resonance imaging Critical Reviews in Biomedical Engineering 42(6): 493-526Dara, D.; Ambardar, A.; Schoneman, W.; Sullivan, S.; Mandojana, J. 1987: Compensation of surface coil shading effects in medical MR imaging Biomedical Sciences Instrumentation 23: 219-221
Yao, W.; Zhao, Y.; Li, B.-y.; Chao, Y.-l.; Du, L. 2008: Effect of simulating static magnetic field of magnetic attachment on osteoblastic morphology and surface ultrastructure Zhonghua Kou Qiang Yi Xue Za Zhi 43(1): 48-49
Linder, B.J.; Kawashima, A.; Woodrum, D.A.; Tollefson, M.K.; Karnes, J.; Davis, B.J.; Rangel, L.J.; King, B.F.; Mynderse, L.A. 2014: Early localization of recurrent prostate cancer after prostatectomy by endorectal coil magnetic resonance imaging Canadian Journal of Urology 21(3): 7283-7289
Hou, S.; Xie, H.; Chen, W.; Wang, G.; Zhao, Q.; Li, S. 2014: Development of RF coil of permanent magnet mini-magnetic resonance imager and mouse imaging experiments Sheng Wu Yi Xue Gong Cheng Xue Za Zhi 31(5): 1023-1030
Laghi, A.; Iafrate, F.; Paolantonio, P.; Iannaccone, R.; Baeli, I.; Ferrari, R.; Catalano, C.; Passariello, R. 2002: Magnetic Resonance Imaging of the anal canal using high resolution sequences and phased array coil: visualization of anal sphincter complex La Radiologia Medica 103(4): 353-359
Schenck, J.F.; Hart, H.R.; Foster, T.H.; Edelstein, W.A.; Hussain, M.A. 1986: High resolution magnetic resonance imaging using surface coils Magnetic Resonance Annual 1986: 123-160
Hu, W.; Wang, X.; Yang, Y.; Liang, D.; Zhao, F. 2007: Design of a half solenoid coil for optimization of magnetic focusing in trans-cranial magnetic stimulation Sheng Wu Yi Xue Gong Cheng Xue Za Zhi 24(4): 910-913
Nishikiori, O. 1996: Studies on transcranial magnetic stimulation--characteristics of the magnetic coil Nippon Ganka Gakkai Zasshi 100(1): 18-26
Huang, Y.; Du, Y. 2015: Optimization of Three-dimensional Ultrashort Echo time Magnetic Resonance Imaging at a Low Field Sheng Wu Yi Xue Gong Cheng Xue Za Zhi 32(6): 1239-1243
Mafee, M.F.; Campos, M.; Raju, S.; Samett, E.; Mohamadi, H.; Sadighi, S.; Heffez, L.; Friedman, M.; Chow, J.M. 1988: Head and neck: high field magnetic resonance imaging versus computed tomography Otolaryngologic Clinics of North America 21(3): 513-546
Zhang, J-shu.; Chen, X-lei.; Li, F-ye.; Li, J-jiang.; Zheng, G.; Zhang, T.; Hu, S.; Xu, B-nan. 2012: Influences of high-field intraoperative magnetic resonance imaging on the extent of resection in low-grade gliomas Zhonghua Yi Xue Za Zhi 92(25): 1738-1741
Marini, M.; Fazio, V.; Cremona, A.; Galluzzo, M.; Cortese, A. 1995: The role of magnetic resonance imaging with a low-intensity field (0.2 T) in assessing expansive lesions of the hand and wrist La Radiologia Medica 90(3): 202-207
Akisawa, M.; Matsumura, Y.; Kitaoka, H.; Yamasaki, N.; Takata, J.; Doi, Y. 2002: Myocardial enhancement on magnetic resonance imaging with gadolinium-diethylenetriamine pentaacetic acid and improvement of left ventricular function in patients with dilated cardiomyopathy Journal of Cardiology 40(4): 145-152
Underwood, S.R.; Forbar, S.M. 1994: Magnetic resonance imaging of the cardiovascular system Revista Portuguesa de Cardiologia: Orgao Oficial da Sociedade Portuguesa de Cardiologia 13(11): 811-821
Richardson, M.L.; Genant, H.K.; Helms, C.A.; Gillespy, T.; Heller, M.; Jergesen, H.E.; Bovill, E.G. 1985: Magnetic resonance imaging of the musculoskeletal system Orthopedic Clinics of North America 16(3): 569-587
Soulen, R.L.; Higgins, C.B. 1985: Magnetic resonance imaging of the cardiovascular system Magnetic Resonance Annual 1985: 27-43
Mushlin, A.I.; Detsky, A.S.; Phelps, C.E.; O'Connor, P.W.; Kido, D.K.; Kucharczyk, W.; Giang, D.W.; Mooney, C.; Tansey, C.M.; Hall, W.J. 1993: The accuracy of magnetic resonance imaging in patients with suspected multiple sclerosis. the Rochester-Toronto Magnetic Resonance Imaging Study Group JAMA 269(24): 3146-3151
Thiabpha, A.; Hansasuta, A. 2016: Initial Experience with Ultra-Low-Field Intraoperative Magnetic Resonance Imaging in Endoscopic Endonasal Transsphenoidal Surgery for Pituitary Adenoma at Ramathibodi Hospital Journal of the Medical Association of Thailand 99(Suppl 3): S30-S38
Johnston, D.L.; Rokey, R.; Okada, R.D. 1987: Nuclear magnetic resonance imaging of the cardiovascular system Herz 12(1): 51-67