Cerebral oximeter INVOS-3100
Lubnin, A.I.; Shmigel'skiĭ, A.V.; Ostrovskiĭ, A.I.
Anesteziologiia i Reanimatologiia 4: 68-70
1995
ISSN/ISBN: 0201-7563 PMID: 7486203 Document Number: 442905
A new device is described: cerebral oximeter intended for monitoring cerebral oxygenation and early diagnosis of cerebral ischemia and hypoxia. The advantages and shortcomings of the proposed method are analyzed in comparison with other current methods for the early diagnosis of cerebral ischemia.
Document emailed within 1 workday
Related Documents
Decker, M.J.; Dickensheets, D.; Arnold, J.L.; Cheung, P.W.; Strohl, K.P. 1990: A comparison of a new reflectance oximeter with the Hewlett-Packard ear oximeter Biomedical Instrumentation and Technology 24(2): 122-126Buj Fernández, A.; Fábregas Lorenzo, A. 1990: The oximeter Revista de Enfermeria 13(146): 82-84
Gordeev, V.A.; Maksimov, G.I.; Sterlin, I.G.; Tsvik, A.I. 1994: Pulse oximeter OXIPULSE-01 Meditsinskaia Tekhnika 1: 45-47
Macnab, A.J.; Smith, M.; Phillips, N.; Smart, P. 1996: Oximeter reliability in a subzero environment Aviation Space and Environmental Medicine 67(11): 1053-1056
Fernandez, M.; Burns, K.; Calhoun, B.; George, S.; Martin, B.; Weaver, C. 2007: Evaluation of a new pulse oximeter sensor American Journal of Critical Care: An Official Publication American Association of Critical-Care Nurses 16(2): 146-152
Homma, T. 2011: Arterial blood gas analysis, pulse oximeter Nihon Rinsho. Japanese Journal of Clinical Medicine 69(10): 1797-1801
Kondo, T.; Sato, S.; Ashimura, H.; Nishijima, Y.; Akiyoshi, Y.; Takahashi, S.; Yamaguchi, H.; Naito, H. 1993: The usefulness of a pulse oximeter on the postanesthesia round Masui. Japanese Journal of Anesthesiology 42(5): 703-706
Okuda, Y.; Kitajima, T.; Asai, T. 1997: Use of the pulse oximeter for teaching axillary nerve block Regional Anesthesia 22(6): 592
Tan, S.; Ai, Z.; Yang, Y.; Xie, Q. 2013: Design of a pulse oximeter used to low perfusion and low oxygen saturation Zhongguo Yi Liao Qi Xie Za Zhi 37(3): 189-193; 196
Coetzee, A.; Heymann, W. 1988: Detection of changes in arterial haemoglobin saturation with the pulse oximeter South African Medical Journal 73(5): 316-317
Mineo, R.; Sharrock, N.E. 1993: Pulse oximeter waveforms from the finger and toe during lumbar epidural anesthesia Regional Anesthesia 18(2): 106-109
Tremper, K.K.; Perloff, W.; Levine, E.M.; Shippy, C. 1983: More on the performance of the IL282 CO-oximeter in the presence of perfluorochemical emulsion, Fluosol-DA Clinical Chemistry 29(1): 209-210
Kohjiro, M.; Koga, K.; Komori, M.; Fukutome, T.; Yasaka, B.; Urakami, H. 1992: A case report of a burn produced by the probe of a pulse oximeter Masui. Japanese Journal of Anesthesiology 41(12): 1991-1993
Pérez-Padilla, J.R.; Bracamonte-Peraza, R.; Manrique, G.; Ruiz-Primo, M.E. 1986: Accuracy of an the ear oximeter Biox-IIi and its sensitivity to carboxyhemoglobin in Mexico City Archivos del Instituto de Cardiologia de Mexico 56(4): 303-307
Haynes, J.M. 2007: Exclusion of patients limits findings in pulse oximeter study American Journal of Critical Care: An Official Publication American Association of Critical-Care Nurses 16(3): 206 257; Author Reply 257 269
Vreman, H.J.; Stevenson, D.K. 1994: Carboxyhemoglobin determined in neonatal blood with a CO-oximeter unaffected by fetal oxyhemoglobin Clinical Chemistry 40(8): 1522-1527
Pearl, M.L.; Dattel, B.J. 1990: The pulse oximeter for respiratory distress associated with pyelonephritis in pregnancy. A case report Journal of Reproductive Medicine 35(7): 724-726
Wu, X.; Cai, G. 2009: The development of a wearable pulse oximeter sensor and study of the calibration method Sheng Wu Yi Xue Gong Cheng Xue Za Zhi 26(4): 731
Jones, M.; Olorvida, E.; Monger, K.; Yarborough, V.; Bennetts, H.; Harris, D.; Keith, C.; Boggs, L.; Firrincieli, B.; Ingram, L.; Richardson, P.; Locklear, D.; Sigmon, S.; Lewis, J.; Murphy, J. 2015: How well do Inexpensive, Portable Pulse Oximeter Values Agree with Arterial Oxygenation Saturation in Acutely Ill Patients? Medsurg Nursing: Official Journal of the Academy of Medical-Surgical Nurses 24(6): 391-396
Di Pumpo, F.; Ruffino, G.; Malacarne, P. 2019: Pulse oximeter to detect peripheral oxygen saturation in underwater rebreather ECCR diver: a preliminary study Undersea and Hyperbaric Medicine: Journal of the Undersea and Hyperbaric Medical Society Inc 46(1): 1-6