Selective adsorption of cryoglobulins from plasma of three patients with mixed type Ii cryoglobulinemia

Jiménez Klingberg, C.; Borberg, H.; Belac, M.; Späth, P.

Beitrage Zur Infusionstherapie und Transfusionsmedizin 32: 370-373

1994


ISSN/ISBN: 1023-2028
PMID: 9480127
Document Number: 436151
A new immunoadsorption column using Sepharose CL 4B as carrier material and IgG as covalently bound ligand was applied for the treatment of three patients with mixed type II kryoglobulinaemia. The titers of rheumatoid factors and cryoglobulins could be significantly decreased during each treatment. The removal of both correlated with the clinical improvement. Skin ulcers, refractory to conventional therapy and arthropathical complaints decreased considerably or disappeared. Further studies evaluating the pathomechanisms and the predictivity of the results must be performed.