Tetralogy of Fallot with absent pulmonary valve--a successful surgical case at 40 days after birth

Fujino, S.; Hoshino, S.; Harada, Y.; Takemura, T.; Tagusari, O.; Yamazaki, K.

Nihon Kyobu Geka Gakkai 41(11): 2239-2244

1993


ISSN/ISBN: 0369-4739
PMID: 8283100
Document Number: 417384
A markedly symptomatic patient with tetralogy of Fallot and absent pulmonary valve underwent operation at 40 days after birth. The baby had severe cardiopulmonary insufficiency at neonatal period and needed surgical intervention. The operation is consisted of patch closure of ventricular septal defect, partial resection of dilated pulmonary artery, and right ventricular outflow reconstruction with unicusped prosthetic patch. The patient is growing and is well more than 2 years and 8 months after operation.