Gas chromaographic analysis of Kelthane technical
Black, R.F.; Kurtz, C.P.; Baum, H.
Journal - Association of Official Analytical Chemists 54(5): 1237-1240
1971
ISSN/ISBN: 0004-5756 PMID: 5151688 Document Number: 41281
A new gas chromatographic method for the analysis of Kelthane and minor impurities is under investigation. The separation is made on a 6′ glass column packed with 3% Oronite Polybutene 128 on Gas-Chrom Q, using temperature programming from 135 to 205°C. Retention time data for all known components in Kelthane Technical are reported. Work on a quantitative procedure for the determination of active ingredients and minor impurities, utilizing an internal standard (methyl myristate), is in progress.
Document emailed within 1 workday
Related Documents
Gelin, J.; Ducimetiere, P.; Kahn, J.; Rochemaure, J.; Lenègre, J. 1971: Automatic analysis of the electrocardiogram. Tests of an analysis program and technical considerations Archives des Maladies du Coeur et des Vaisseaux 64(4): 587-604O'Shea, B.M.; McGennis, A.J.; Vero, P.M. 1983: Prescribing psychotropics: Part I. An analysis of technical information Irish Medical Journal 76(3): 135-137
Ruiz Merino, J. 1975: Technical standards of microbiological analysis of drinking water Revista de Sanidad E Higiene Publica 48(2): 89-114
Moser, R. 1973: Technical contribution to fetal blood analysis sub partu Geburtshilfe und Frauenheilkunde 33(7): 592-594
Longhini, C.; Portaluppi, F.; Arslan, E.; Pedrielli, F.; Ravenna, F.; Toselli, T. 1979: Technical and methodological aspects concerning the application of Fourier's analysis to phonocardiography Giornale Italiano di Cardiologia 9(3): 329-330
Ramshaw, B.J.; Tucker, J.G.; Duncan, T.D.; Heithold, D.; Garcha, I.; Mason, E.M.; Wilson, J.P.; Lucas, G.W. 1996: Technical considerations of the different approaches to laparoscopic herniorrhaphy: an analysis of 500 cases American Surgeon 62(1): 69-72
Nosek, T.M.; Leal-Cardoso, J.H.; Perlitz, V.; Sloop, S.L.; Godt, R.E. 1992: Technical problems related to the analysis of the effects of inorganic phosphate on cardiac muscle Brazilian Journal of Medical and Biological Research 25(7): 727-743
Cervera-Paz, F.J.; Manrique, M.; Huarte, A.; García, F.J.; García-Tapia, R. 1999: Study of surgical complications and technical failures (correction of technical defects) of cochlear implants Acta Otorrinolaringologica Espanola 50(7): 519-524
Molinari, G.; Sardanelli, F.; Caponnetto, S. 1995: Cardiac magnetic resonance: the technical indications and a technical glossary Cardiologia 40(8): 541-550
Gudov, V.F. 1976: Medical-technical basis for creation of functional eye prosthesis - technical means for compensation of poor vision and blindness Oftalmologicheskii Zhurnal 31(4): 289-293
Hernández, A.R.; San Sebastián, M. 2014: Assessing the technical efficiency of health posts in rural Guatemala: a data envelopment analysis Global Health Action 7: 23190
Simmons, D.; Rowan, J.; Reid, R.; Campbell, N.; Simmons, D.; Campbell, N.; Rowan, J.; Norris, M.; Bent, P.; Beckford, B.; Williams, L.; Dawson, S.; Moore, P.; Wilson, C.; Perwick, C.; Mulligan, E.; Waller, N.; White, I.; Valgrae, J.; Elder, R.; Reid, R.; Simmers, D.; Berger, K. 2008: Screening, diagnosis and services for women with gestational diabetes mellitus (GDM) in New Zealand: a technical report from the National GDM Technical Working Party New Zealand Medical Journal 121(1270): 74-86
Falini, B.; Mason, D.Y.; Stein, H.; Moir, D.J.; Zuccaccia, M.; Grignani, F.; Martelli, M.F. 1984: The immunohistological analysis of undecalcified human bone marrow trephine biopsies. Technical and diagnostic aspects Haematologica 69(3): 346-376
Säuberli, H.; Laube, W. 1983: Is technical progress in the diagnosis of acute abdomen in daily practice fiction or reality? Analysis of 660 cases Schweizerische Medizinische Wochenschrift 113(15): 559-561
Sotirow, B. 1971: Critical analysis of the pathomechanical assumptions as well as some technical faults in surgical treatment of paralytic talipes calcaneus Chirurgia Narzadow Ruchu i Ortopedia Polska 36(4): 513-517
Jat, T.R.; Sebastian, M.S. 2013: Technical efficiency of public district hospitals in Madhya Pradesh, India: a data envelopment analysis Global Health Action 6: 21742
Liu, H.C.; Li, C.; Zhang, F.; Wang, X.S.; Zhang, C.; Luo, H.X.; Song, J.; Yu, P.W.; Tang, B. 2019: Analysis on the technical characteristics and clinical efficacy of robotic-assisted intersphincteric resection for patients with low rectal cancer Zhonghua Wei Chang Wai Ke Za Zhi 22(12): 1137-1143
Perronne, C.; Adjagba, A.; Duclos, P.; Floret, D.; Houweling, H.; Le Goaster, C.; Lévy-Brühl, D.; Meyer, Fçois.; Senouci, K.; Wichmann, O. 2016: Implementing efficient and sustainable collaboration between National Immunization Technical Advisory Groups: Report on the 3rd International Technical Meeting, Paris, France, 8-9 December 2014 Vaccine 34(11): 1325-1330
Perronne, C.; Adjagba, A.; Duclos, P.; Floret, D.; Houweling, H.; Le Goaster, C.; Lévy-Brühl, D.; Meyer, Fçois.; Senouci, K.; Wichmann, O. 2016: Implementing efficient and sustainable collaboration between National Immunization Technical Advisory Groups: Report on the 3rd International Technical Meeting, Paris, France, 8-9 December 2014 Vaccine 34(11): 1325-1330
Perronne, C.; Adjagba, A.; Duclos, P.; Floret, D.; Houweling, H.; Le Goaster, C.; Lévy-Brühl, D.; Meyer, Fçois.; Senouci, K.; Wichmann, O. 2016: Implementing efficient and sustainable collaboration between National Immunization Technical Advisory Groups: Report on the 3rd International Technical Meeting, Paris, France, 8-9 December 2014 Vaccine 34(11): 1325-1330