Use of the newly designed long-handled forceps for respiratory surgery
Ishioka, T.; Shuto, K.; Koyama, K.; Kudo, T.; Yamauchi, N.; Ishikawa, T.
Kyobu Geka. Japanese Journal of Thoracic Surgery 45(2): 136-137
1992
ISSN/ISBN: 0021-5252 PMID: 1542189 Document Number: 397191
We report on use of the newly designed long-handled forceps for respiratory surgery. The forceps have a curved-end in the same plane as its handles. This contributes to the easier clamping of vessels running horizontally in the deep fields. It is very useful not only in thoracic surgery, such as respiratory and esophageal surgery, but also in pelvic surgery.
Document emailed within 1 workday
Related Documents
Moon, H.J. 2010: Minimally invasive vas surgery using a newly designed double-ringed clamp World Journal of Urology 28(2): 205-208Endoh, M.; Oizumi, H.; Kanauchi, N.; Kato, H.; Ota, H.; Suzuki, J.; Watarai, H.; Nakamura, M.; Sadahiro, M. 2016: Removal of foreign bodies from the respiratory tract of young children: Treatment outcomes using newly developed foreign-body grasping forceps Journal of Pediatric Surgery 51(8): 1375-1379
Zimin, I.V.; Vereshchagina, L.V.; Kozlova, L.I. 1990: Respiratory function in newly developed stenocardia and in long-term course of ischemic heart disease Klinicheskaia Meditsina 68(2): 69-74
Phillips, S.J.; Romanowski, E. 1972: A newly designed venous cannula for cardiopulmonary bypass Journal of Thoracic and Cardiovascular Surgery 63(5): 769-770
Sharma, M.I.; Rao, C.K. 1981: A newly designed device for sampling cyclops densities Journal of Communicable Diseases 13(4): 227-234
Urano, Y. 2013: In vivo cancer detection with a newly designed fluorescent probe Gan to Kagaku Ryoho. Cancer and ChemoTherapy 40(3): 299-303
Bae, D.K.; Mun, M.S.; Kwon, O.S. 1997: A newly designed miniplate staple for high tibial osteotomy Bulletin 56(3): 167-170
Vesely, R. 2008: Retooling wellness. Health plans rolling out newly designed programs to help employers cut costs Modern Healthcare 38(46): 34 36 38
Saenghirunvattana, R.; Tantivitayatan, K.; Chumnanvech, W.; Tangsukkasemsun, S.; Siritongtaworn, P. 2008: A comparison study between newly-designed pencil-point and cutting needles in spinal anesthesia Journal of the Medical Association of Thailand 91(Suppl 1): S156-S161
Stabholz, A.; Babayof, I.; Mann, J. 1996: The clinical effect of a newly designed electric toothbrush on supragingival plaque, gingivitis and gingival bleeding Journal of Clinical Dentistry 7(1): 17-20
Shindoh, T.; Matsuura, N.; Sugitachi, A.; Saitoh, K. 2002: A study of the oncolytic effect of a newly designed CDDP system on an experimental animal model with carcinomatous ascites Gan to Kagaku Ryoho. Cancer and ChemoTherapy 29(12): 2195-2198
Kikuchi, G.; Yamasaki, Y.; Takiguchi, M.; Nakamura, T.; Yabuta, Y.; Kato, H.; Amano, M.; Inoue, H. 1982: A clinical study of one-lung anesthesia using a newly designed endotracheal tube with a movable endobronchial blocker (UNI-VENT) Masui. Japanese Journal of Anesthesiology 31(10): 1156-1161
Ishigaki, T.; Sakuma, S.; Watanabe, M. 1988: Computer-assisted rotation and multiple stationary irradiation technique. Newly designed overrunning multi-leaf collimators for conformation radiotherapy European Journal of Radiology 8(2): 76-81
Walss Rodríguez, R.J.; Casillas Cantú, A. 1984: Immediate materno-fetal morbidity in the use of forceps. Comparative study of divergent and crossed forceps Ginecologia y Obstetricia de Mexico 52(325): 121-125
Thornhill, J.A.; Hartman, J.; Boon, G.D.; Riviere, J.E.; Jacobs, D.; Ash, S.R. 1984: Support of an anephric dog for 54 days with ambulatory peritoneal dialysis and a newly designed peritoneal catheter American Journal of Veterinary Research 45(6): 1156-1161
Misra, P.; Guru, P.Y.; Sen, A.B. 1989: In vitro culture of erythrocytic stages, including gametocytes of Plasmodium berghei (NK 65 strain) using candle jar method and a newly designed continuous medium flow apparatus Indian Journal of Experimental Biology 27(12): 1039-1043
Kawakami, T.; Watanabe, F.; Iju, M.; Takahashi, J.; Matsuura, M.; Kuroshima, S.; Sugie, S. 1981: Cardiac function study to the isolated canine heart by use of newly designed perfusion apparatus and continuous automatic analysis of hemodynamic datas by new type microcomputor system Nihon Kyobu Geka Gakkai 29(1): 41-47
Hruda, J.; Horváth, P.; Sulc, J.; Tůma, S.; Ruth, C.; Lízler, J. 1993: Long-term follow-up of the quality of life in children after surgery for vascular compression of the respiratory tract Ceskoslovenska Pediatrie 48(9): 517-520
Osterland, U.; Kraft, M.; Böhm, B.; Boenick, U. 1997: Development of a bipolar clamp forceps for minimal invasive surgery Biomedizinische Technik. Biomedical Engineering 42 Suppl: 113-114
Bodner-Adler, B.; Bodner, K.; Kimberger, O.; Wagenbichler, P.; Mayerhofer, K. 2003: Management of the perineum during forceps delivery. Association of episiotomy with the frequency and severity of perineal trauma in women undergoing forceps delivery Journal of Reproductive Medicine 48(4): 239-242