Hydroxyapatite-coated total hip prosthesis. 3d-generation hip prostheses
Mikic, S.; Pfirrmann, R.W.
Zentralblatt für Chirurgie 115(11): 695-705
1990
ISSN/ISBN: 0044-409X PMID: 2385971 Document Number: 358466
Since 1987, 80 hydroxyapatite-coated (HA) cementless total hip prostheses have been implanted. Thirty patients were examined 21 months post-operatively and the results compared with data for uncoated prosthesis. Earlier mobilisation and freedom from pain, together with evidence of bone ingrowth without connective tissue membrane formation, confirmed the benefits of HA-coated prostheses.
Document emailed within 1 workday
Related Documents
Egol, K.A.; Lonner, J.H.; Jaffe, W.L. 1998: Simultaneous bilateral total hip arthroplasty with hydroxyapatite coated implants Bulletin 57(1): 52-55Gallo, J.; Landor, I.; Cechová, I.; Jahoda, D. 2008: Comparison of Hydroxyapatite-coated stems in total hip arthroplasty after a minimum 10-years follow-up Acta Chirurgiae Orthopaedicae et Traumatologiae Cechoslovaca 75(5): 339-346
D'Antonio, J.A.; Capello, W.N.; Manley, M.T.; Feinberg, J. 1997: Hydroxyapatite coated implants. Total hip arthroplasty in the young patient and patients with avascular necrosis Clinical Orthopaedics and Related Research 344: 124-138
Pupka, A.; Janczak, D.; Skóra, J.; Barć, P.; Pawłowski, S.ła.; Ruciński, A. 2009: The use of the synthetic silver coated prosthesis and penduculated omentum flap in the treatment of prostheses infection Polimery W Medycynie 39(3): 57-60
He, Y.-x.; Gu, Y.-f.; Cao, H.-p.; Chang, C.-k.; Mao, D.-l. 2002: Histomorphometric osseointegration evaluation of hydroxyapatite-coated and non-coated implants in dogs Shanghai Kou Qiang Yi Xue 11(4): 335-339
McAuley, J.P.; Moore, K.D.; Culpepper, W.J.; Engh, C.A. 1998: Total hip arthroplasty with porous-coated prostheses fixed without cement in patients who are sixty-five years of age or older Journal of Bone and Joint Surgery. American Volume 80(11): 1648-1655
Ariely, E. 1975: Construction of total prostheses for patients with insufficient prosthesis support Zwr 84(14): 650-654
Tankersley, W.S.; Mont, M.A.; Hungerford, D.S. 1997: A second-generation cementless hip prosthesis: improved results over the first-generation prosthesis American Journal of Orthopedics 26(12): 839-844
Katzner, M.; Petit, R.; Schvingt, E. 1975: Replacement of the proximal end of the femur by total cervicodiaphysary prosthesis. (Special large size total prosthesis). With 13 case reports Annales de Chirurgie 29(2): 97-101
Moroni, A.; Aspenberg, P.; Toksvig-Larsen, S.; Falzarano, G.; Giannini, S. 1998: Enhanced fixation with hydroxyapatite coated pins Clinical Orthopaedics and Related Research 346: 171-177
Moyen, B.; Santini, R.; Comtet, J.J.; Morancho, R.; Ghommidh, J.; Constant, G. 1983: Biological behavior of hydroxyapatite-coated carbon implants Revue de Chirurgie Orthopedique et Reparatrice de l'Appareil Moteur 69(Suppl 2): 79-82
Tufekci, E.; Brantley, W.A.; Mitchell, J.C.; McGlumphy, E.A. 1997: Microstructures of plasma-sprayed hydroxyapatite-coated Ti-6Al-4V dental implants International Journal of Oral and Maxillofacial Implants 12(1): 25-31
Block, M.S.; Gardiner, D.; Kent, J.N.; Misiek, D.J.; Finger, I.M.; Guerra, L. 1996: Hydroxyapatite-coated cylindrical implants in the posterior mandible: 10-year observations International Journal of Oral and Maxillofacial Implants 11(5): 626-633
Søballe, K.; Hansen, E.S.; Brockstedt-Rasmussen, H.; Pedersen, C.M.; Bünger, C. 1992: Bone graft incorporation around titanium-alloy- and hydroxyapatite-coated implants in dogs Clinical Orthopaedics and Related Research 274: 282-293
Callahan, B.C.; Lisecki, E.J.; Banks, R.E.; Dalton, J.E.; Cook, S.D.; Wolff, J.D. 1995: The effect of warfarin on the attachment of bone to hydroxyapatite-coated and uncoated porous implants Journal of Bone and Joint Surgery. American Volume 77(2): 225-230
Thomson-Neal, D.; Evans, G.H.; Meffert, R.M. 1989: Effects of various prophylactic treatments on titanium, sapphire, and hydroxyapatite-coated implants: an SEM study International Journal of Periodontics and Restorative Dentistry 9(4): 300-311
Hernández Cortés, P.; Nájera Sagastume, O.O.; Mesa Ramos, F.; Pajares López, M.; Hernández Hernández, M.A. 2002: Hydroxyapatite-coated stems with metaphyseal and diaphyseal press-fit. Eleven-year follow-up results Acta Orthopaedica Belgica 68(1): 24-32
Knox, R.; Lee, K.; Meffert, R. 1993: Placement of hydroxyapatite-coated endosseous implants in fresh extraction sites: a case report International Journal of Periodontics and Restorative Dentistry 13(3): 245-253
Rohrer, M.D.; Sobczak, R.R.; Prasad, H.S.; Morris, H.F. 1999: Postmortem histologic evaluation of mandibular titanium and maxillary hydroxyapatite-coated implants from 1 patient International Journal of Oral and Maxillofacial Implants 14(4): 579-586
Moroni, A.; Rocca, M.; Faldini, C.; Stea, S.; Giardino, R.; Giannini, S. 1999: Hydroxyapatite fully coated conic hip prosthetic stem: a long term animal study Annales Chirurgiae et Gynaecologiae 88(3): 198-204