Usefulness of long-term monitoring of neonatal arterial pressure

Menghetti, E.; Cugini, P.; Felici, W.; Tucciarone, L.; De Santis, F.; Di Feo, G.; Di Russo, C.; Intini, E.; Mariani, M.; Olivo, G.

La Pediatria Medica e Chirurgica Medical and Surgical Pediatrics 12(1): 61-63

1990


ISSN/ISBN: 0391-5387
PMID: 2377565
Document Number: 351285
30 newborns were studied, whose systolic arterial pressure has been controlled every 30 minutes 48 hours long, with oscillometric automatic technique. The resulting average of oscillation was 45.1 +/- 12.8 mmHg for systolic pressure and 36 +/- 11.4 mmHg for diastolic pressure. Wide pressure oscillations, you can find in some newborns, could be related with the development of a future pressure hypertension, and therefore a long term pressure monitoring would turn to a real useful test to single out future hypertensive subjects.