Metal implants of the coxal femur in the elderly patient should not be removed
Dannöhl, C.
Aktuelle Traumatologie 19(4): 180-182
1989
ISSN/ISBN: 0044-6173 PMID: 2572160 Document Number: 332628
Document emailed within 1 workday
Related Documents
Imhäuser, G. 1974: Fractures of the coxal end of the femur in the child Hefte Zur Unfallheilkunde 117: 309-314Okhotskiĭ, V.P.; Suvalian, A.G.; Malygina, M.A. 1989: Surgical treatment of trochanteric fractures of the femur in middle-aged and elderly patients using a bunch of metal rods Ortopediia Travmatologiia i Protezirovanie 10: 55-58
Tikhonenko, E.S.; Pozdnikin, I.I. 1977: Salter operation associated with corrective osteotomy of the femur in treatment of coxal dysplasia in children Vestnik Khirurgii Imeni I. I. Grekova 118(6): 97-99
Chan, F.W.; Bobyn, J.D.; Medley, J.B.; Krygier, J.J.; Tanzer, M. 1999: The Otto Aufranc Award. Wear and lubrication of metal-on-metal hip implants Clinical orthopaedics and related research 1999(369): 10-24
Wu, B.; Dai, M.; Zou, F.; Zhang, B.; Li, B.; Luo, S.; Qiu, P. 2013: Effectivenes of anterolateral C-shaped approach in treatment of intertrochanteric fracture of femur in elderly patient Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi 27(8): 985-989
Rozman, J.; Pihlar, B.; Strojnik, P. 1988: Surface examination of electrodes of removed implants Scandinavian Journal of Rehabilitation Medicine. Suppl 17: 99-103
Dikhtenko, G.I.; Pelipenko, V.P. 1973: Acute cholecystitis after metal osteosynthesis of the femur Klinicheskaia Khirurgiia 10: 65-66
El-Mahady, A.S.; Amin, M.; Fahmy, T.H.; Abbas, N.A. 1984: Comparison between endosseous metal blade-vent and endosseous polymer-coated metal blade-vent implants when used as distal abutment for removable appliances in free-end saddle cases Egyptian Dental Journal 30(2): 141-154
Matharu, G.S.; Berryman, F.; Brash, L.; Pynsent, P.B.; Treacy, R.B.; Dunlop, D.J. 2018: The effectiveness of blood metal ions in identifying bilateral metal-on-metal total hip arthroplasty patients at risk of adverse reactions to metal debris Acta Orthopaedica Belgica 84(2): 154-162
Leitz, G. 1970: Hazards in use of metal and plastic implants Zeitschrift für Allgemeinmedizin 46(27): 1337-1339
Slooff, T.J. 1973: Ossifications as a reaction on metal implants Acta Orthopaedica Belgica 39(Suppl 1): 63-68
Schmelzle, R.; Schwenzer, N. 1977: Bridging of mandibular lesions with metal implants Deutsche Zahnarztliche Zeitschrift 32(4): 329-331
Karagianes, M.T.; Wheeler, K.R.; Nilles, J.L. 1975: Cartilage repair over porous metal implants Archives of Pathology 99(7): 398-400
Feldman, R.M. 1980: The use of diathermy in the presence of metal implants and cardiac pacemakers Canadian Medical Association Journal 123(1): 16-17
Ohnsorge, J. 1972: Ion-optical studies on the passive layer of metal implants Zeitschrift für Orthopadie und ihre Grenzgebiete 110(6): 962-964
Zubikov, V.S. 1986: Osteosynthesis using metal plates in the treatment of the sequelae of para- and intra-articular fractures of the femur and tibia Khirurgiia 11: 110-113
Cohen, J. 1998: Current concepts review. Corrosion of metal orthopaedic implants Journal of Bone and Joint Surgery. American Volume 80(10): 1554
Oron, U.; Alter, A. 1984: Corrosion in metal implants embedded in various locations of the body in rats Clinical Orthopaedics and Related Research 185: 295-300
Sivash, K.M.; Berman, A.M.; Sherepo, K.M.; Morozov, B.P.; Shapiro, I.L. 1979: Response of the compact bone to the mechanical action of metal implants Ortopediia Travmatologiia i Protezirovanie 3: 54-56
Talib, R.J.; Toff, M.R.M. 2004: Plasma-sprayed coating of hydroxyapatite on metal implants--a review Medical Journal of Malaysia 59 Suppl B: 153-154