Finite element stress analysis of root-form implants
Rieger, M.R.
Journal of Oral Implantology 14(4): 472-484
1988
ISSN/ISBN: 0160-6972 PMID: 3270697 Document Number: 320738
Document emailed within 1 workday
Related Documents
Akça, K.ç; Cehreli, M.C.; Iplikçioglu, H. 2002: A comparison of three-dimensional finite element stress analysis with in vitro strain gauge measurements on dental implants International Journal of Prosthodontics 15(2): 115-121Szucs, A.; Divinyi, T.ás.; Bojtár, I.; Polgár, K.; Nasztanovics, F.; Füstös, A.; Lorincz, A.; Barabás, J.óz. 2006: A biomechanical study of the mechanical stress transmission of dental implants using finite element analysis. Part II. Experiments Fogorvosi Szemle 99(5): 187-193
Liang, D.-k.; Wang, J.-h.; Ma, Q.-s.; Lu, Y.-p.; Zhu, R.-f. 2002: The influence of the screw thread and the height of constraints on the stress distribution around dental implants by using three-dimensional finite element analysis Shanghai Kou Qiang Yi Xue 11(4): 324-326
Szucs, A.; Divinyi, Tás.; Lorincz, Aám. 2006: A biomechanical study of the mechanical stress transmission of dental implants using finite element analysis. Review of literature. Part I Fogorvosi Szemle 99(4): 141-147
Xu, S.; Cheng, X.; Hua, X. 1997: Three-dimensional finite element stress analysis of magnetical retaining and bar retaining in overdenture implants Zhonghua Kou Qiang Yi Xue Za Zhi 32(2): 105-107
Satoh, T.; Maeda, Y.; Komiyama, Y. 2005: Biomechanical rationale for intentionally inclined implants in the posterior mandible using 3D finite element analysis International Journal of Oral and Maxillofacial Implants 20(4): 533-539
Luo, X.; Ouyang, G.; Ma, X. 1998: Three dimensional finite element analysis on the mandibular complete overdenture supported by nature roots or implants Zhonghua Kou Qiang Yi Xue Za Zhi 33(5): 303-305
Eser, A.; Akça, K.ç; Eckert, S.; Cehreli, M.C. 2009: Nonlinear finite element analysis versus ex vivo strain gauge measurements on immediately loaded implants International Journal of Oral and Maxillofacial Implants 24(3): 439-446
Namba, R.S.; Keyak, J.H.; Kim, A.S.; Vu, L.P.; Skinner, H.B. 1998: Cementless implant composition and femoral stress. a finite element analysis Clinical Orthopaedics and Related Research 347: 261-267
Chai, Z.-W.; Li, L.-H.; Song, J.-L.; Deng, F.; Fan, Y.-B. 2009: Three-dimensional finite element analysis of stress distribution in mandible advanced with Forsus Zhonghua Kou Qiang Yi Xue Za Zhi 44(5): 293-296
Segundo, R.ên.M.H.; Oshima, H.M.S.; Silva, I.N.L.; Júnior, L.H.B.; Mota, E.G.; Coelho, L.F.B. 2007: Stress distribution on external hexagon implant system using 3d finite element analysis Acta Odontologica Latinoamericana: Aol 20(2): 79-81
Nakamura, T.; Imanishi, A.; Kashima, H.; Ohyama, T.; Ishigaki, S. 2001: Stress analysis of metal-free polymer crowns using the three-dimensional finite element method International Journal of Prosthodontics 14(5): 401-405
Meira, J.B.C.; Braga, R.R.; de Carvalho, A.C.P.; Rodrigues, F.áv.P.; Xavier, T.A.; Ballester, R.Y. 2007: Influence of local factors on composite shrinkage stress development--a finite element analysis Journal of Adhesive Dentistry 9(6): 499-503
Hu, J.; Zhang, F.; Dai, N.; Li, S.; Gu, W.; Ma, J. 2012: Finite element stress analysis of all-ceramic crown of the upper central incisor in differential thickness Hua Xi Kou Qiang Yi Xue Za Zhi 30(4): 356-359
Viţalariu, A.; Comăneci, R.; Tatarciuc, M. 2006: Analysis on the stress induced by non metallic posts in dental and periodontal support by using the finite element method Revista Medico-Chirurgicala a Societatii de Medici Si Naturalisti Din Iasi 110(3): 705-710
Li, Z.; Chen, Y.; Liu, J. 2003: Analysis of stress in the periodontal tissue of the maxillary first molar on distal movement by finite element method Hua Xi Kou Qiang Yi Xue Za Zhi 21(4): 267-269
Chen, J.; Esterle, M.; Roberts, W.E. 1999: Mechanical response to functional loading around the threads of retromolar endosseous implants utilized for orthodontic anchorage: coordinated histomorphometric and finite element analysis International Journal of Oral and Maxillofacial Implants 14(2): 282-289
Sertgöz, A. 1997: Finite element analysis study of the effect of superstructure material on stress distribution in an implant-supported fixed prosthesis International Journal of Prosthodontics 10(1): 19-27
Zheng, L.; Yang, J.; Hu, X.; Luo, J. 2014: Three dimensional finite element analysis of a novel osteointegrated dental implant designed to reduce stress peak of cortical bone Acta of Bioengineering and Biomechanics 16(3): 21-28
Sun, B.; Fan, Y.; Liu, Z.; Qian, Y.; Mu, Y. 2007: Three-dimensional finite element stress analysis of mandibular unilateral distal-extension with extra-coronal precision attachment Sheng Wu Yi Xue Gong Cheng Xue Za Zhi 24(1): 116-119