Specimen collection in plastic containers gives rise to interferents in liquid-chromatographic assay of cyclosporine
Maguire, S.; Kyne, F.; UaConaill, D.
Clinical Chemistry 33(8): 1493-1494
1987
ISSN/ISBN: 0009-9147 PMID: 3608183 Document Number: 297426
Document emailed within 1 workday
Related Documents
Wollmann, H.; Skaletzki, B.; Richter, J. 1979: Liquid-liquid extraction for the quantitative determination of sorbed drugs in polyethylene. Part 40: Contributions to the problems of the use of plastic containers for liquid dosage forms Die Pharmazie 34(3): 153-155Beyrich, T.; Tibussek, P. 1981: Studies on the light transmittance of coloured plastic bottles for liquid pharmaceutical preparations. Part 43: Contributions to problems concerning the use of plastic containers for liquid pharmaceutical preparations Die Pharmazie 36(5): 337-341
Beyrich, T.; Lüdde, H. 1978: Radiographic determination of polyethylene and polypropylene crystallinity. 2. The effect of pharmaceutically relevant factors on the crystallinity index of PE and PP plastic containers. 31. Problems of filling plastic containers for fluid drug preparations Die Pharmazie 33(2-3): 93-96
Wollmann, H.; Skaletzki, B.; Schaaf, A. 1974: Determination of polarity of drugs. 14. Contributions to problems of use of plastic containers for liquid drug preparations Die Pharmazie 29(10-11): 708-711
Yuan, Y.; Zhao, F. 1997: Immunologically prepared plasma specimen of albuterol for high performance liquid chromatographic determination Se Pu 15(1): 12-14
Pohloudek-Fabini, R.; Jira, T. 1983: Analysis and stability of atropine sulfate and scopolamine hydrobromide. 2. Quantitative determination of the alkaloid in its decomposition product; 79. contribution to problems concerning the use of plastic containers for liquid pharmaceuticals Die Pharmazie 38(6): 390-392
Shah, A.K.; Sawchuk, R.J. 1988: Improved liquid-chromatographic determination of cyclosporine and its metabolites in blood Clinical Chemistry 34(7): 1467-1471
Higgins, D. 2008: Specimen collection. Part 2--Obtaining a catheter specimen of urine Nursing Times 104(18): 26-27
Jira, T.; Pohloudek-Fabini, R. 1983: Analysis and stability of atropine sulfate and scopolamine hydrobromide. 3: Studies on the stability of tropane alkaloids; 80: contribution to problems in the use of plastic containers for liquid pharmaceuticals Die Pharmazie 38(8): 520-523
Annesley, T.; Matz, K.; Balogh, L.; Clayton, L.; Giacherio, D. 1986: Liquid-chromatographic analysis for cyclosporine with use of a microbore column and small sample volume Clinical Chemistry 32(7): 1407-1409
Jamani, A.; Pudek, M.; Schreiber, W.E. 1989: Liquid-chromatographic assay of urinary porphobilinogen Clinical Chemistry 35(3): 471-475
Sanders, C.A.; Moore, E.S. 1986: Liquid-chromatographic assay of cefuroxime in plasma Clinical Chemistry 32(11): 2109
Luke, D.R.; Matzke, G.R.; Clarkson, J.T.; Awni, W.M. 1987: Improved liquid-chromatographic assay of labetalol in plasma Clinical Chemistry 33(8): 1450-1452
Houglum, J.E.; Tasler, M.K. 1996: Liquid chromatographic assay of tylosin in animal feeds Journal - Association of Official Analytical Chemists 79(2): 369-374
Mehvar, R.; Jamali, F.; Pasutto, F.M. 1988: Liquid-chromatographic assay of ibuprofen enantiomers in plasma Clinical Chemistry 34(3): 493-496
Cowlishaw, M.G.; Sharman, J.R. 1986: Liquid-chromatographic assay of cefoperazone from plasma and bile Clinical Chemistry 32(5): 894
Lam, G.; Huang, S.M.; Lee, M.G.; Nation, R.L.; Chiou, W.L. 1979: Obviating interference with liquid-chromatographic assay of theophylline Clinical Chemistry 25(10): 1862-1863
Bieva, C.J.; Ladmirant, I.H.; Scheirs, I.; Dardenne, J.P. 1987: Administered viloxazine interferes in liquid-chromatographic assay of normetanephrines Clinical Chemistry 33(9): 1677-1678
Brisson, A.M.; Fourtillan, J.B. 1981: Human pharmacokinetics of cerfuroxime by high-performance liquid chromatographic assay Therapie 36(2): 143-149
Smith, H.T.; Robinson, W.T. 1984: Semi-automated high-performance liquid chromatographic method for the determination of cyclosporine in plasma and blood using column switching Journal of Chromatography 305(2): 353-362